Instruction manual
8526-M256-O1 Rev B • CS Series 
19
GRAVITY ADJUSTMENT 
IMPORTANT! This scale is equipped with a Gravity Adjustment function which 
allows the scale to be calibrated in one location and then adjusted to match the 
gravity at the location where it will be used. 
During the Gravity Adjustment process, it is necessary to enter 
values using the scales alphanumeric keypad. In addition, the 
following keys are also used: 
KEY FUNCTION 
• (decimal) 
Exit without saving setting 
CE 
Move the cursor left (backward) 
TARE 
Move the cursor right (forward) 
MC 
Enter (exit and save setting) 
Enter Gravity Adjustment 
1.  With the scale in the Weight mode (0 will be displayed for WEIGHT and  will be 
displayed for the PIECE WEIGHT and COUNT displays), press the ZERO key. 
2.  When the WEIGHT display shows dashes (@@@@@), press the • (decimal point) key. 
3.  The WEIGHT display will change to `0. Press the TARE key. 
4.  The WEIGHT display will change to `4. Press the MC key. 
5.  The WEIGHT display will change to ` (with the first 0 flashing). 
6.  Use the alphanumeric keypad to enter 0 and 2. 
7.  The WEIGHT display will change to ` with the 2 flashing. 
8.  Press the MC key. 
9.  The PIECE WEIGHT display will change to show the current number of times the 
gravity adjustment has been changed and the COUNT display will show the current 
gravity adjustment value. 
10.  Press the MC key. 
11.  The first digit on the COUNT display will start to flash. 
12.  Use the alphanumeric keypad to enter the new gravity adjustment value. 
13.  Press the MC key. 
14.  The WEIGHT display will change to `4. 
15.  Press the • (decimal point) key. 
16.  The scale will return to the Weight mode (0 will be displayed for WEIGHT and  
will be displayed for the PIECE WEIGHT and COUNT displays). 
17.  The scale is ready for normal use. 
NOTE! By default, the USA gravity adjustment value will be used. Consult the factory 
Tech Support for the gravity adjustment value for your location. 