Instruction manual

8526-M256-O1 Rev B CS Series
17
OPERATIONAL SETUP, CONT.
0` – Accumulation Acceptable Condition 1
1. With the WEIGHT display showing 0` with the 0 flashing, press the 1 key on
the alphanumeric keypad.
2. The WEIGHT display will change to 0` with the right 1 flashing.
3. Press the MC key.
4. The PIECE WEIGHT display will change to show the current setting.
5. If the setting displayed is acceptable, press the MC key to save it.
6. Otherwise, select the desired setting for the Accumulation Acceptable Condition 1
setting and press the MC key to save it.
 = The scale will accept accumulation only when the weight is stable.
 = The scale will accept accumulation no matter if the weight is stable or not.
0` – Accumulation Acceptable Condition 2
1. With the WEIGHT display showing 0` with the second 1 flashing, press the 2
key on the alphanumeric keypad.
2. The WEIGHT display will change to 0` with the 2 flashing.
3. Press the MC key.
4. The PIECE WEIGHT display will change to show the current setting.
5. If the setting displayed is acceptable, press the MC key to save it.
6. Otherwise, select the desired setting for the Accumulation Acceptable Condition 2
setting and press the MC key to save it.
 = The scale will only accept the next accumulation data when the weight returns to zero.
 = The scale will accept the next accumulation data no matter if the weight returns to
zero or not. When there is a load on the scale, the weight can be accumulated
continuously.
= The weight must return to zero Gross weight before the scale can accept the next
accumulation data.
Operational Setup is Complete
1. With the WEIGHT display showing 0` with the 2 flashing, press the (decimal
point) key.
2. The WEIGHT display will change to `0.
3. Press the (decimal point) key again.
4. The scale will return to the Weight mode (0 will be displayed for WEIGHT and
will be displayed for the PIECE WEIGHT and COUNT displays).
5. The scale is ready for normal use.