Instruction manual

8526-M256-O1 Rev B CS Series
7
OPERATION
Power Switch
The Power Switch is located on the bottom left side
panel towards the front of the scale. Place the
power switch in the on position. The scale will
perform a brief lamp test. This test consists of
illuminating all display segments and annunciator
LED’s to allow the operator to make a visual
verification that the display is operational. After
completion of the lamp test, the scale will display the
model number and software revision level, then the
WEIGHT display will show zero weight, indicating
the scale is ready for use.
Metric Conversion
To change weighing units, press the UNITS key to toggle between pounds and kilograms.
Note that either the lb or kg annunciator will illuminate to indicate which weighing unit is
active.
Before using the scale, it should be “warmed up” (turned on and unloaded
for approximately 15 to 20 minutes).
WEIGHT Display
Displaying Weight
1. With the scale in the Weight mode (0 will be displayed for WEIGHT and will be
displayed for the PIECE WEIGHT and COUNT displays), place the item to be weighed
on the scale platform.
2. The display will show the weight on the scale platform. The lb or kg annunciators will
illuminate to indicate which unit of weight has been selected and that the scale is in the
Weight mode. Note that the PIECE WEIGHT and COUNT display will remain at 0
(zero).
Zero the WEIGHT Display
1. With the scale in the Weight mode ( will be displayed for the PIECE WEIGHT and
COUNT displays), press the ZERO key.
2. The WEIGHT display will show @@@@@@ (six dashes) for a few seconds and then
return to 0. The ZERO and Stable annunciators will illuminate, indicating a
center-of-zero, stable gross weight condition.
ON/OFF Switch