Specifications

8200-M538-O1 Rev C y 225 Installation & Technical
95
ID STORAGE OPERATION, CONT.
Gross Weight Alarm
If 96#.#4/;'5 was selected in the ID Storage Menu setup, the indicator will display
and activate a PRESET soft key. By using the PRESET key, a gross weight can be
programmed to turn on the PWC1 control output for a programmed time (1-99 seconds) when
the gross weight exceeds the programmed weight.
#.#4/9629%::::::
To program the alarm gross weight and alarm on time, press the PRESET key. The
display will show #.#4/9629%::::::. Using the numeric keys, enter the
desired alarm gross weight and press the ENTER key. The preset weight will be stored
and the display will change to show the alarm 6+/'10: parameter.
IMPORTANT! The gross weight must fall below 1/2 the preset weight
before the alarm is re-armed.
6+/'10:
Using the numeric keys, enter the desired alarm 6+/'10: value (1-99 seconds) and
press the ENTER key. The on time will be stored and the display will return to normal
mode. Note that setting 6+/'10
disables the alarm.