Specifications
8200-M538-O1 Rev C y 225 Installation & Technical
93
COUNT OPERATION
Counting
.You must select .(601,during Setup and Calibration to enable the COUNT key
and Counting functions.
Sampling and Counting
1. With the indicator in the Gross Weight mode () on the display), press the COUNT key.
The display will show #&&2%5 if no previous sample has been taken or %1706
if a sample has previously been taken.
2. If #&&2%5is displayed, proceed to step 4.
3. If %1706 is displayed, press the COUNT key again to change the display to show
#&&2%5then continue to step 4.
4. If needed, press the COUNT key again to step to the next sample quantity. Continue
pressing the COUNT key until the desired value is displayed.
Note, that pressing the COUNT/SAMPLE key repeatedly will cause the sample
quantity to step in the following sequence: 5, 10, 25, 50, 75, 5, 10, etc.
5. When the displayed value (for the sample size) is acceptable, press the ENTER key.
6. Otherwise, use the numeric keys to enter a new value (for the sample size) and then
press the ENTER key to save it and proceed with the counting operation.
7. Add the indicated sample quantity and press the ENTER key.
8. Add the pieces to be counted and read total the count
9. Press the NET/GROSS key to complete the counting operation and return to normal
operation.
Counting Out From a Container
1. Place the filled container on the scale platform and press the TARE key.
2. The display will show zero weight and 0'6 to indicate the weight is Net weight.
3. Press the COUNT key.
4. Remove a sample piece from the container and press the ENTER key.
5. Remove the pieces from the container and read the total number removed.
6. Press the NET/GROSS key to complete the counting operation and return to normal
operation.
NOTES
y As the need for counting accuracy increases, the size of the sample must also increase.
y As individual uniformity of the parts decrease, the sample size must increase.
y Manual counting errors may occur if samples larger than necessary are used.
y Because of variation of individual container weights, be certain to "tare off" each
container by placing the empty container on the scale and pressing the ZERO key
before proceeding with the count operation.