Specifications

8200-M538-O1 Rev C y 225 Installation & Technical
86
CALIBRATION AND SETUP, CONT.
Using the numeric keys, enter the value for the new backlight turn-on level and then press
the ENTER key to save the new setting and return to SETUP MENU #3. Allowable values
are 0 through 99.
NOTE! The value selected must be less than the .KIJVU value to activate.
$#%-.+6' $#%-.+6' $#%-.+6'::
Backlight always ON Backlight always OFF Level that backlight
turns ON at
PASSWORD
2#55914& (PASSWORD)
The password setup parameter determines whether a password is required to enter
Calibration and Setup on indicators programmed for international use (75#01). If the
indicator is programmed for domestic use (75#;'5) the password parameter WILL NOT
be displayed on SETUP MENU #3.
With the SETUP MENU #3 displayed press the 3 key and then the ENTER key. The display
will change to show 2#55914&::::::::::::. Note that XXXXXXXXXXXX is the
current password if a password was previously entered, otherwise only 2#55914& will
be displayed.
If the setting displayed is acceptable, proceed to the next setup parameter. Otherwise,
using the alphanumeric keys, enter up to 12 characters for the password and then press the
ENTER key to save the new setting and return to the SETUP MENU #3.
PASSWORD OPERATION
With a PASSWORD set, anytime the operator tries to enter Calibration and Setup, the
display will show the 2#55914& prompt requiring the operator to enter the correct
password. If the wrong password is entered, the indicator displays ERROR momentarily
and returns to the weight mode. Note that the password is not shown on the display when
the operator is entering it.
NOTE! It is recommended to write the password down and store it in a secure
location. If the password is forgotten or lost and a change to the indicator setup
is required, the indicator must be reprogrammed. WARNING! Reprogramming
the indicator will ERASE ALL the contents of the Nov-Ram and memory.