Specifications
8200-M538-O1 Rev C y 225 Installation & Technical
128
VIEW AUDIT TRAIL COUNTERS
A Category 1 Audit Trial is provided on the Model 225 with two event counters that increment
when a change is made to features that are required by NTEP or OIML to be sealed. One
counter is designated for calibration parameters and one is designated for configuration
changes as required in NCWM Publication 14, 2007. Each event counter has a capacity to
record 999 changes. The data for the counters is maintained in non-volatile memory and can
be viewed or printed by a weights and measures inspector. When selected, the display will
show a 3-digit number representing the Calibration and Configuration counters.
To View the Audit Trail Counters
With the indicator ON, press the SHIFT key and then press the Navigation ENTER key (red
square key in center of the Navigation arrows). The display will change to show the
SETUP/REVIEW MENU.
5'6724'8+'9/'07
'06'4%#.+$4#6+10#0&5'672
8+'9#7&+664#+.%1706'45
%#.+$4#6'5%#.'
&'.%7561/6+%-'6
24+065'672
'PVGT5GNGEVKQP@':+6
8+'9#7&+664#+.%1706'45
With the SETUP/REVIEW MENU displayed, press the 2 key and then the ENTER key.
The display will change to show COUNTER MENU.
%1706'4/'07
%#.+$4#6+10%1706'4:::
%10(+)74#6+10%1706'4:::
2TGUU24+06MG[VQRTKPVEQWPVGTU
2TGUUCP[QVJGTMG[VQ':+6
%#.+$4#6+10%1706'4 (CALIBRATION COUNTER)
The %#.+$4#6+10%1706'4::: is the current value for the number of
times the 225 has been calibrated.
%10(+)74#6+10%1706'4 (CONFIGURATION COUNTER)
The %10(+)74#6+10%1706'4::: is the current value for the number of
times the 225 has had a configuration change.
Press the PRINT key to print the counters using the selected printer port enabled during
Calibration and Setup. Otherwise, press any key (alphanumeric, soft or the navigation keys)
on the keypad to exit and return to the SETUP/REVIEW MENU.