Specifications

8200-M538-O1 Rev C y 225 Installation & Technical
122
TROUBLESHOOTING
Error Codes
The Model 225 indicator is equipped with software that indicates when an error in the
operation takes place. The following lists the error codes displayed by the 225 along with their
meaning. Should you encounter an error code, please refer to this list for the cause.
#0#.1)*+)*
»»»»»»»
1. The load cell input is above the allowed range of the indicator.
CORRECTIVE ACTION: Check for improper load cell wiring, excessive load, and for
output of 1 to 40mV.
2. Load cell or circuit failure.
CORRECTIVE ACTION: Consult your scale service provider.
#0#.1).19
»»»»»»»
1. The load cell input is below the allowed range of the indicator.
CORRECTIVE ACTION: Check for improper load cell wiring and for output of 1 to 40mV.
2. Load cell or circuit failure.
CORRECTIVE ACTION: Consult your scale service provider.
18'4%#2
»»»»»»»
The load on the scale exceeds the scale capacity (105% of capacity if 75#;'5 or plus 9
divisions if 75#01). May indicate miscalibration.
CORRECTIVE ACTION: Remove the over capacity load from the scale platform. Consult
your scale service provider regarding recalibration.
%*'%-/#6.
In a Digital Fill Control or Batcher operation configured for decumulative operation
(#%%7/.#6';'5) there is not enough material to start the operation.
CORRECTIVE ACTION: Determine the reason for the error display and take the
appropriate corrective action.
%*'%-<'41
In a Digital Fill Control or Batcher operation with &7/2)#6';'5 and #761
6#4'01 the weight is above the zero tolerance value.
CORRECTIVE ACTION: Determine the reason for the error display and take the
appropriate corrective action.