Specifications

8200-M538-O1 Rev C y 225 Installation & Technical
109
PRESET WEIGHT COMPARATORS OPERATION
5'65%#.' (SET SCALE)
1. With the display showing the values of the enabled PWCs presets or trim weights, press
the 1 and 8 keys and then the ENTER key.
5:5:5:
5:5:5:
5:5:5:
5:5:5:
5:
5:5'664+/
5:
5:5'65%#.'
'06'4
VQ':+6QT29%61%*#0)'
24'5'6
2. The display will change to show the scale that each enabled PWC is associated with.
Note that X is the current value for each preset.
3. If the values displayed for each preset are acceptable, press the ENTER key to exit and
return to normal operation.
4. Otherwise, use the numeric key to select the PWC# (1 to 16) scale association to
change and then press the ENTER key. The display will change to show the current
scale association (5%.:) of the preset selected.
5. Using the numeric keys, enter the new value for the preset scale association and then
press the ENTER key to save the new setting.
6. Continue with this procedure until a value for each preset scale association to be used
has been entered.
7. After the last preset scale associated has been entered, press the ENTER key to exit
and return to normal operation.
NOTE! To select the TOTAL scale, enter a 4 at the 5%. prompt.
Enter Preset Values Completed
After entry of the presets, trim weight and scale associations are complete, operation may
begin. Press the ENTER key to exit and return to normal operation. Note that the Preset
Weight Comparators are always active unless a zero preset value was entered for the preset.
IMPORTANT! Remember that the preset weight comparators function
operates on the absolute value of the weight ignoring the polarity.