Table 1. Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
NOTE
When hammer is rotated back to cocked position, burst cam should rotate to allow
burst disconnector to latch in next notch.
Step 6. Determine if burst cam spring (11) fails to "clutch" and burst cam (12) fails to rotate back
with hammer (10).
Replace burst cam spring. If problem continues, replace hammer and burst cam
(WP 0023).
Step 7. Inspect for broken front hook (29) on burst disconnector (30).
Replace burst disconnector (WP 0021).
1 v s 0 2 5
M 1 6 A 2 / M 1 6 A 4 a n d M 4
3 0
2 9
1 1
1 2
1 0
Figure 23. Burst Disconnector and Burst Cam Inspection.
Step 8. Check for short recoil.
See Malfunction 10.