Technical data

TM 9-1005-319-23&P 0015
0015-7
1 v s 1 1 1
2 0
2
8
2 1
2 2
2 0
Figure 11. Removal of Handguard Slip Ring.
WARNING
To avoid injury to eyes, use care when removing spring-loaded parts.
16. Remove retaining ring (20) using retaining ring pliers.
17. Remove slip ring spring (22) and handguard slip ring (2).
18. Do not remove barrel nut (21) from barrel assembly (8).
END OF TASK
CLEANING
WARNING
CARBON REMOVING COMPOUND
NOTE
A small arms cleaning brush (bore) (WP 0045, item 4) may be used to clean interior
of front sight assembly where gas tube is secured.
Use carbon removing compound (WP 0045, item 8) to remove carbon deposits from interior and exterior of
gas tube. If a large amount of carbon is found and cannot be removed, replace gas tube.
END OF TASK