Technical data

TM 9-1005-319-23&P 0012
0012-5
WARNING
DRY CLEANING SOLVENT
3. Use penetrant kit (WP 0045, item 27) to check for cracks in bolt (4) as follows:
a. The area to be inspected must be clean, free of oil, etc. Spray a small amount of remover on the
area to be inspected, let dry and wipe off with a wiping rag.
b. Spray penetrant (only enough to wet the area) on the area of the bolt (4) to be inspected.
c. Spray developer over the penetrant and let the developer work. Cracks will be indicated by a
change in color where there is a crack. If there are cracks, the component is unserviceable.
d. Pay close attention to the area where the locking lugs (10) meet the body.
e. If there are no cracks, spray remover on the area; let dry and wipe off with a wiping rag. Oil the
area to prevent corrosion.
f. Replace bolt assembly if bolt (4) is defective.
1 v s 0 8 7
4
1 1
Figure 7. Inspection of Firing Pin Hole.
NOTE
Bolts with firing pin holes which permit the special no-go plug gage to fully penetrate
at any position on the circumference will be rejected and replaced.
4. Test bolt (4) for elongated or oversized firing pin hole using special no-go plug gage (11) P/N 12620101.
NOTE
Replacement of the bolt assembly will require that the headspace be tested; see
WP 0015.
END OF TASK