User manual
Andover Continuum
Andover Continuum
Network & Communications-11
Third Party Interfaces
PUMPS
Manufacturer Equipment*
Descrip./Model
Driver
Type
TAC File
Reference
Number*
Infinity
Compatible
1
st
Generation
Continuum
Compatible
2
nd
Generation
Continuum
Compatible
Driver
Description
Grundfoss Genibus Pumps
& Motors
X E01-0210-172
3 3
Full control and monitoring of
pumps and motors on RS-485
Genibus network.
SECURITY SYSTEMS
Manufacturer Equipment*
Descrip./Model
Driver
Type
TAC File
Reference
Number*
Infinity
Compatible
1
st
Generation
Continuum
Compatible
2
nd
Generation
Continuum
Compatible
Driver
Description
Guardall PX,Windsor
Panels
X E01-0210-177
3 3
Set/unsetareas,isolate/de-isolate
and monitor alarm and tamper
conditions for all detectors.
Honeywell/
Microtec
Galaxy X E01-0210-183
3 3 3
AllowstheUsertoset,unset,partset
andresetgroups,resetthepanel,
monitor conditions of circuits; and
monitor,set,andalarmconditions
of groups. The latest version can link
directly to the Pelco Endura XDriver
for fast cause & effect actions.
Scope
Communica-
tions
Scope RX
10 Intruder
system
X
E01-0210-220
3 3
Provides a link between Continuum
and the Scope RX10 programmable
POCSAG receiver. This allows alarm
data sent from an IRIS (Intelligent
Radio Information System) to a
Scope RX10 to be captured as
alarms and events in Continuum.
SENSORS/METERS
Manufacturer Equipment*
Descrip./Model
Driver
Type
TAC File
Reference
Number*
Infinity
Compatible
1
st
Generation
Continuum
Compatible
2
nd
Generation
Continuum
Compatible
Driver
Description
Siko AEA Linear
Position Sensor
X E01-0210-192
3 3
Part of a MAGLINE micro Linear
Positioning System. Has an MSA
Sensor to sense the position along
a magnetically-encoded measuring
strip.
* These options are available to download from TAC ExchangeOnline if the appropriate XDriver comm port has been enabled.
UPS SYSTEMS
Manufacturer Equipment*
Descrip./Model
Driver
Type
TAC File
Reference
Number*
Infinity
Compatible
1
st
Generation
Continuum
Compatible
2
nd
Generation
Continuum
Compatible
Driver
Description
MGE UPS Comet UPS X E01-0210-118
3 3 3
Modbus RTU is used to extract
data from the MGE units.
Note: The Comet UPS actually
uses JBUS which is a smaller set
of Modbus RTU commands.
TELEPHONE SWITCHES/SYSTEMS
Manufacturer Equipment*
Descrip./Model
Driver
Type
TAC File
Reference
Number*
Infinity
Compatible
1
st
Generation
Continuum
Compatible
2
nd
Generation
Continuum
Compatible
Driver
Description
AT&T TBOS X E01-0210-188
3 3
Supports TBOS Protocol.