User manual

Andover Continuum
Network & Communications-8
Third Party Interfaces
Third Party Interfaces
FIRE SYSTEMS
Manufacturer Equipment*
Descrip./
Model
Driver
Type
TAC File
Reference
Number*
Infinity
Compatible
1
st
Generation
Continuum
Compatible
2
nd
Generation
Continuum
Compatible
Driver
Description
ActionAir LNS System X E01-0210-238
3
The Actionair LNS System consists
ofaPanelPC,UPSandpre-loaded
software. The system communicates
with the smoke fire damper interfaces
(SFDI) to provide intelligent control
and monitoring of Actionair motorised
dampers (Control modes).
Clymac Ziton Fire
Panel
X
E01-0210-223
3 3
Allows monitoring of Fire Panel data on
a Ziton ZP3 fire System using XDriver
points in Continuum. The XDriver may
monitorAlarm,Fault,Enabled/Disabled
conditions on individual Devices Zones
or Loops in the Ziton Fire System.
Cerberus X E01-0210-231
3
Provides a link between Continuum
andanetworkofCerberusrepanels,
monitoring of a Cerberus fire alarm
system from the Continuum front-end.
Edwards Fast panel
IRC-3
X E01-0210-189
3 3
Requires CM1N control module with
printer port.
Edwards EST-3 Printer
Protocol
X E01-0210-221
3 3
Operates through the EST-3 printer
interface to allow monitoring of
Fire Panel. It allows the monitoring
ofdetectorssuchasAlarms,Faults,
Disablements and Enablements.
Gamewell Series 600
Analog/
Addressable
Fire Alarm
Control Panel
X E01-0210-193
3 3 3
Allowsremoteacknowledgment,silence,
andresetactions,aswellasremote
monitoring of alarm and fault conditions
fromthepanel,itscircuits,anddevices.
Supports both a single panel and
networked panel.
Gent 3400 Panel X E01-0210-152
3 3
Uses both Plain English and XDriver filter
to map all points from Fire Panel.
How/Face
Macanda
Proton Panel X E01-0210-143
3
Monitoronly,willneedmodicationsfor
Continuum as it contains data files.
Kentech Kentech
Synchro Panel
X
E01-0210-216
3 3
This enables a standalone Kentech
panel,ornetworkofpanelstobe
integratedintoContinuum,allowing
fire and fault monitoring.
Protec Algo-Tec,
6400MXL
Series
X E01-0210-222
3 3 3
ThisXDrivermaymonitoralarm,
fault,enable/disableconditionson
individual zones or loops in the Protec
Fire System. The latest version can link
directly to the Pelco Endura XDriver for
fast cause & effect actions.
Simplex 4020,4100,
4120
X E01-0210-186
3 3
Uses Simplex 4100 Computer Port
Protocol-Format 1.
Simplex 4020,4100,
4120 Series
X E01-0210-184
3 3
Uses BACnet PTP/RS-232 to
communicate through a Simplex
BACpac Portal to communicate to the
Simplex fire control panel. Read only.
Tyco TycoMX X E01-0201-226
3 3 3
Integrates Continuum with Tyco MX Fire
Panels in a network environment and
simulates a Fire Panel Node on the Tyco
network. Changes in device or panel status
are mapped across to the Netcontroller.
Vesda Mini,ED-70,
Scanner
X E01-0210-118
3 3 3
Uses Modbus interface to map all smoke
Scanner detection system points.
* These options are available to download from TAC ExchangeOnline if the appropriate XDriver comm port has been enabled.