User manual

Andover Continuum
BACnet
Andover Continuum
BACnet Controllers-3
BACnet BACnet
TheAndoverContinuumbCX1SeriesisaseriesofNativeBACnetroutersandcontroller/routers,
which head up the BACnet family of Continuum controllers. These controllers reside at the
networklevelandrouteBACnetmessagesbetweenBACnet/IP,BACnetoverEthernet,andMS/
TPnetworks.TheycanalsoserveasBACnetBroadcastManagementDevices(BBMD),allowing
for routing of messages between IP networks.
There are two basic bCX1 models: the bCX1-R (Router Only) and the bCX1-CR (Controller/Router).
ThebCX1-RmodelprovidesallthefunctionalitytoroutemessagesbetweenBACnetnetworks,
and the bCX1-CR is a full-function BACnet Building Controller (B-BC). The bCX1-CR performs
the routing functions of the bCX1-R with the additional power of a programmable controller with
expansion I/O capabilities.
•B-BC–BACnetBuildingControlleravailableinRouter-onlyandRouter/Controller
combinationmodels
•Supports18BACnetobjecttypesincludingTrends,Schedules,Calendars,andLoops
•
NativeBACnet/IPandMS/TPcommunicationsforinteroperabilitytothirdpartysystems
•10/100Ethernetport
•BACnetBroadcastMessageDevice(BBMD)support
•ExpandableforlocalI/OanddisplayusingxPExpansionModules
•AdvancedFlashMemoryprovidesutmostreliability–storesapplicationprogramme,
operatingsystem,andrun-timedata
•Flashmemoryallowseasyonlinesoftwareupdates
•SupportforcustomEmbeddedWebServer
•SNMPMonitoring
•SNMPAlarmingOption
•SupportforBACnetTrendobject
•SupportforBACnetCalendarandScheduleobjects
•BTLListedB-AACControllerwithlocalTrends
Technical Specifications
Power: 24VAC,+10%-15%,50/60Hz,12-28VDCautosensing
OperatingEnvironment: 0to+49°C,10–95%RH(non-condensing)
Dimension: 139mm (H) x 213mm (W) x 62mm (D)
Battery:
Replaceable,rechargeablebattery.Provides30daystypical
accumulated power failure backup of RAM memory. All data
stored in Flash on power loss.
Memory: 32MBSDRAM,16MBFLASH
bCX1-R-64 BCX1-R-64
Routeronly,64MS/TPnodes
bCX1-CR-0 0 NODE BCX1-CR-0
Controller/Router,0NodeSupport,BACnet
bCX1-CR-8 8 NODE BCX1-CR-8
Controller/Router,8NodeSupport,BACnet
bCX1-CR-32 32 NODE BCX1-CR-32
Controller/Router,32NodeSupport,BACnet
bCX1-CR-64 64 NODE BCX1-CR-64
Controller/Router,64NodeSupport,BACnet
bCX1-CR-127 127 NODE BCX1-CR-127
Controller/Router,127NodeSupport,BACnet
BACnet Controller / Router bCX1 Series