User manual

Andover Continuum
Infinet Controllers-8
Infinet
Infinet
DO-6-TR Output Module
6digitaloutputs,FormAopticallyisolatedtriacs(0.5A,24VAC).PWMcontrolof0.1seconds.
Combine2outputsinto1tri-state.Powerrequirementsare24VDC,1.1watts.Minimum
current required for correct switching is 30mA. No DC loads.
Output Module DO-6-TR
AC-1 Input/Output Module
FullI/Oforonedoororportal.1reader/keypadinput,handlingeithercomboreader/keypad
unitsorseparateunits.Wiegandorproximityreadersonly.3supervisedinputs,2FormC
outputs,(5A,24VAC/DC)withlocaloverrideandfeedback.Powerrequirementsare24VDC,2.6
watts (plus reader power requirements). Reader power on-board 5V/120mA. 2 Site codes stored
for degrade mode operation.
Wiegand AC-1
AC-1A Input/Output Module
FullI/Oforonedoororportal.1reader/keypadinput,handlingeithercomboreader/keypad
unitsorseparateunits.Wiegandorproximityreadersonly.3Supervisedinputs,2FormC
outputs(5A,24VAC/DC)withlocaloverrideandfeedback.Powerrequirementsare10-28VDC,
2.6 watts (plus reader power requirements). Reader power on-board: 5V/50mA. 2 Site codes
stored for degrade mode operation.
Wiegand AC-1A
AC-1 Plus Input/Output Module
EnhancedI/Oforonedoororportal.1reader/keypadinput,handlingeithercombination
reader/keypadunits,magneticstripereaders,proximityreaders,ABAformatorWiegand
cardkeyreaders.5supervisedinputs.2FormCoutputs(5A,24VAC/DC)withlocaloverride
andfeedback.Powerrequirementsare10-28VDC,2.6watts(plusreaderpowerrequirements).
Reader power on-board: 5V/50mA. 4 Site codes stored for degrade mode operation.
Wiegand/ABA AC-1Plus
ACC-LON FTT (Free Topology Transceiver) I/O Modules
AllContinuumI/OmodulesarealsoavailablewithanACC-LONFTTinterface,whichprovides
increased flexibility and reliability for your installation. FTT modules are connected using a
twisted-paircableandcanbewiredinabus,star,distributedstar,orevenaringtopology
for added resilience. Third party repeaters and converters are available for special applications
(FTT-to-fibre,FTT-to-leased-line,etc.).Also,eachmoduleisprotectedwith1500Vtransformer-
coupled isolation.
For ACC-LON FTT compliant modules add -FT to the end of the Part Number when ordering
Example**-**-*-FT=DO-4-R-O-FT
Note:
TheCX9900NetControllermustalsobeconfiguredforFTToperation.
NetControllers I & II I/O Modules
NetControllers I & II Display Modules