User manual
Andover Continuum
Infinet
Andover Continuum
Infinet Controllers-3
Infinet Infinet
TheContinuumbCX1isafeature-rich,yetcost-effectivenetworkcontrollerthatsupportsthe
Infinet family of field controllers.
The controller provides a full function 10/100 Ethernet connection and support for up to 127
Infinetfieldcontrollers,withasecondcommunicationportavailableforamodemconnectionor
a Plain English™ driver. This full function network controller provides global control for all of its
field controllers and a simple easy-to-use web configuration interface. The bCX1 also provides a
TCP/IPinterfaceforcustomwebpages,alongwithSNMPmonitoringandoptionalSNMPalarm
delivery. The bCX1 also has the ability to add expansion I/O for local control via the xP family of
expansion modules.
•10/100EthernetPort
•ExpandableforLocalI/OandDisplayusingAndover’sxPExpansionModules
•AdvancedFlashMemoryProvidesUtmostReliability–StoresApplication
Programme,OperatingSystem,andRun-timeData
•FlashMemoryAllowsEasyOn-LineSoftwareUpdates
•Dial-inCommunicationsSupport
•SupportforCustomEmbeddedWebServer
•SNMPMonitoring
•SNMPAlarmingOption
•XDriveOptionSupport
•RedundantAlarmingSupport
Technical Specifications
Power: 24VAC,+10%-15%,50/60Hz,12-28VDCautosensing
OperatingRange: 0to+49°C10–95%RH(non-condensing)
Dimensions: 139mm (H) x 213mm (W) x 62mm (D)
Battery: Replaceable,rechargeablebattery.Provides30daystypical
accumulated power failure backup of RAM memory. All data
stored in Flash on power loss.
Memory: 32MBSDRAM,16MBFLASH
Inputs/Outputs
I/O expansion port for the addition of up to two Andover xP expansion modules
bCX1-CR-0-INF 0 NODE bCX1-CR-0-INF
Controller/Router,0NodeSupport,Infinet
bCX1-CR-8-INF 8 NODE bCX1-CR-8-INF
Controller/Router,8NodeSupport,Infinet
bCX1-CR-32-INF 32 NODE bCX1-CR-32-INF
Controller/Router,32NodeSupport,Infinet
bCX1-CR-64-INF 64 NODE bCX1-CR-64-INF
Controller/Router,64NodeSupport,Infinet
bCX1-CR-127-INF 127 NODE bCX1-CR-127-INF
Controller/Router,127NodeSupport,Infinet
XDriver Support
TurnyourbCX1intoapowerfulgatewaybyenablingoneofthebCX1’stwocomm.portsas
anXDriverport.WithanXDriverinstalled,theAndoverContinuumsystembecomesintegrated
withthirdpartyequipment,allowingcommoncontrolfromPlainEnglishprogrammesaswell
asmonitoringandsetpointadjustmentfromCyberStationorweb.Client.Thisoptionmaybe
purchased with new bCX1 controllers or as an upgrade to an existing bCX1.
XDriver XDriver
Modbus/IP and Modbus/RTU XDrivers
Withtheinitialreleaseofthisfeature,twoXDrivershavebeencompiledforthebCX1
–Modbus
®
/IP and Modbus/RTU. Modbus has been the most popular XDriver on the
NetController.Thisopenprotocolcanbefoundonawiderangeofbuildingequipment–RTUs,
powermeters,chillers,breakerpanels,variablespeeddrives,andsoon.TheModbus/RTUdriver
is used with Modbus equipment that is networked using RS-485 wiring and the Modbus/IP
driver is used with Modbus equipment that is networked over Ethernet.
Modbus/IP Modbus/IP
Modbus/RTU Modbus/RTU
Controller/Router Series bCX1 Series