User's Manual
4
"SIREN" activates the SIREN / STROBE( if these are installed) upon a Geo-fence transgression. These are
accessories not normally supplied with RAM3G. The sirens we supply will trigger on a pulse from RAM3G
and remain on for a period set by an internal timer in the siren. Cutting the wires to the siren will not disable it
once activated.
"NOSIREN" disables the Siren and Strobe if issued before a transgression is activated. If the Siren is
already activated, it will not turn it off. It will be up to the siren internal timer to time-out and reset itself. This
command only stops further triggering of external alarm devices. Contact us for other programmable siren
activation options.
SPECIAL COMMANDS
"REPORT xy//info" sets RAM3G up to send an AUTOMATIC "INFO" report every "xy" hours.
"TEMPRESET" alone, resets the Temperature Logs to present ambient temperature.
"TEMPRESET <>F(
or C)<> Max Temp// Min temp " F or C selects units, <> is a space, Max and Min
temps sets the maximum and Minimum ALERT temperatures, Range is 14 F (-10 C) to 176 F ( 80 C).F:
Fahrenheit,
C: Centigrade. Eg: TEMPRESET F 110//38
"HELP" responds with Help info on command syntax.
TEMPDEL n Temperature delay in minutes (n). Use to reduce transient alarms.
PWRDEL n Power loss alert delay in minutes (n). Use to reduce transient alarms.
ARM Activates SMS messaging ( Factory default)
DISARM Disables all SMS messaging.
ASK<>code Used in USSD enabled networks to request network subscriber data like prepaid simcard
balance amount. If code to get simcard dollar balance is say *120# from your cellphone,
then send RAM3G the code as ASK *120# and it will return the network message with this
information. Does not work with voice-only services. Requires USSD service.
PLE Power Loss alert ENABLE.
PLD Power Loss alert DISABLE.
EXTVOLT ON//v.v Alarm voltage setpoint for low voltage alert. Sets value to send alarm.
Eg EXTVOLT ON//11.8 Use in conjunction with PWRDEL delay time value to avoid
transient alarms. OFF/ON.
E1D n Add a Time delay of n minutes to switch n. Use to avoid transient alarms.
DATARESET Resets configuration to Factory default. Use with care. Custom changes will be lost.
CTXSO<n><space><msg> Change Switch (n) OPEN message to "msg".
CTXSC<n><space><msg> Change Switch (n)CLOSED message to " msg".
COMMAND STRINGS
RAM3G will accept multiple commands in the same text message as long as they are each separated by a
semi colon.
eg; GETSIG;INFO;TAMPER;SIREN;FIX
QUESTIONS and TROUBLESHOOTING
Please refer to our website for Frequently asked questions and troubleshooting guidelines.