Technical data
3 Installation
3.1 Electrical data of the Units
3.1.1. Unit Performance (2,5KW, 3KW)
Inductions unit 1-phase (Voltage 230Volt +5% / -10%)
Connection Color Frequency Fuse
Phase Black 50 Hz / 60 Hz Empty
N Blue Working
frequency
Control fuse
1 X 400mA T
(time lag)
Ground Yellow/Green
3.1.2. Unit Performance (3,5KW)
Inductions unit 1-phase ( Voltage 230Volt +5% / -10%)
Connection Color Frequency Fuse
Phase Black, Brown or 1 50 Hz / 60 Hz 2 X 20A FF
(super-quick)
N Blue or 2 Working
frequency
Control fuse
2 X 160mA T
(time lag)
Ground Yellow/Green 22-35 kHz
3.1.3. Unit Performance (5KW)
Inductions unit 3-phases ( Voltage 400Volt +5% / -10%)
Connection Color Frequency Fuse
Phase Black, Brown or 1,
2, 3
50 Hz / 60 Hz 3 X 12,5A FF
(super-quick)
N Blue or 4 Working
frequency
Control fuse
2 X 100mA T
(time lag)
Ground Yellow/Green 22-35 kHz
3.1.4. Unit Performance (7KW,8KW)
Inductions unit 3-phases ( Voltage 400Volt +5% / -10%)
Connection Color Frequency Fuse
Phase Black, Brown or 1,
2, 3
50 Hz / 60 Hz 3 X 16A FF
(quick)
N Blue or 4 Working
frequency
Control fuse
2 X 100mA T
(time lag)
Ground Yellow/Green 22-35 kHz
Installations-environment
- max. ambient temperature
Storage >-20°C bis +70°C in Function >+5°C bis +35°C
- max. relative Atmospheric humidity
Storage > 10% bis 90% in Function > 30% bis 90%