Product specifications

2012 SAMSUNG 
System Air Conditioner
2012 SAMSUNG 
System Air Conditioner
94
95
Clean and Refreshing ERV / ERV PLUS
Features of ERV / ERV PLUS
ERV PLUS System Structure
Get Fresh Air without
Temperature Loss
Maintain the Best Indoor 
Humidity Level
Smart CO
2
 Sensor and
Humidity Stat
Direct Expansion Coil
ERV PLUS is equipped with a direct expansion coil to pre-
condition the outdoor air that enters your indoor environment. 
Outdoor air will pass through the DX coil to produce fresh air 
without any temperature loss.
Humidifier Element (Optional)
Maintain the best indoor humidity level with our clean 
humidifier kit. Samsung’s humidifier kit boasts high efficiency 
humidification with its large humidification area. Its self 
cleaning function, which sprays water from the top of the 
device when the set starts, also prevents bad smells.
ERV automatically operates to give fresh air into the room by 
detecting CO
2
 with the CO
2
 sensor (optional). You can also 
attach a humidity stat (procured locally) which will detect the 
humidity of the room and adjust its humidity level.
Detects indoor and outdoor temperature
to switch to auto mode or execute cold
climate control function.
Temperature Sensor
The fan is used to intake outdoor
air or exhaust indoor air.
Supply/Exhaust Fan
Prevents heat exchanger element 
contamination or blockage caused 
by accumulated dust.
Dust Filter
Exchange temperature and humidity
between the supply and exhaust air.
Heat Exchanger Element
The mode can be switched between heat
recovery ventilation and normal ventilation.
(Availability varies on the type of model.)
Damper
Heating and cooling mode selection
is available after turning on the 
ventilation due to the new DX Coil 
that can heat and cool.
Direct Expansion (DX) Coil
Electrical parts for product control
Control Box
A natural evaporating type humidifier 
is applied to produce more refreshing 
indoor air.
Humidifier element (Optional)
Heat Recovering Method of
ERV System
ERV PLUS
ERV
Damper
tt
Direction Expansion (DX) Coil
t
Humidifier Element (Optional)
t
Supply/Exhaust Fan
tt
Dust Filter
tt
Heat Exchanger Element
tt
Control Box
tt
Temperature Sensor
tt
1
Great ventilation efficiency is achieved with a 2-way 
ventilation design that has air inlets and outlets on 
both sides of the units.
2
The remaining surface of the heat exchanging area 
is specially processed and structured to exchange 
heat energy while preventing the discharged 
contaminants from re-entering.
3
Energy is recovered up to 70% (differs depending 
on the model) of the energy needed to cool or heat. 
This maintains the indoor temperature and humidity 
during the winter, and prevents outdoor heat and 
moisture from entering indoors during the summer.
Direct
Expansion
Coil
Humidifier
element
O
2
O
2
O
2
CO
CO
CO
Moisture
CO
CO
O
2
O
2
Heat
Heat Recovered & Fresh Air
Polluted & Cold Air
Dust
Dust
Polluted & Humid Air Cold & Dry Air
Polluted & Cold Air
Polluted & Humid Air Cold & Dry Air
OutdoorIndoor
O
2
O
2
O
2
CO
CO
CO
Heat Recovered & Fresh Air










