Product specifications

2012 SAMSUNG
System Air Conditioner
2012 SAMSUNG
System Air Conditioner
22
23
Eco-friendly
Easy Installation & Maintenance
High External Static Pressure
Automatic Pipe Length Recognition
Multi-step Diagnosis Function
To properly deal with unexpected various installation
conditions, DVM PLUS IV is designed to manage high external
static pressures up to 8mmAq.
The system provides evenly powerful cool and warm air, regardless of the distance.
8mmAq
10m
40m
Power check
(Opposite phase, Open phase)
Communication check
(Between Indoor/Outdoor units)
Main/Fan board
Sensor open/short
Save S/N and Option value
Operation check
- Compressor operation
- Fan operation
Service valve locking check
Pipe length
Refrigerant amount judgment
(Optional function)
4 W/W operation
(in Heating operation)
EEV malfunction
(in Heating operation)
Self sensor diagnose
(Possible section)
Self fan diagnose
Compressor operation current
Cycle status
(DSH)
PWM valve
Liquid valve
Oil gas valve
Hot gas valve
4-Way valve
(in Cooling operation)
EVI EEV
Indoor EEV opening problem
Incorrect HR piping connection
(Optional function)
S/V lock
(Oil balancing)
Save diagnosed data
Displays error
STEP1
STEP2
STEP3
STEP4
STEP5
Comm. & Sensor Check
Operation Status Check
Major Parts Check
Valve Check
Data Backup
Decreased CO
2
Emission
R410A Refrigerant
Europe Eco-friendly RoHS
Technology Certification
WEEE
DVM PLUS IV is a highly efficient product that adopts
advanced eco-friendly technology to reduce carbon dioxide
(CO
2
) emissions.
- CO
2
emission level: Data based on 0.42kg/kWh
- Time period: 5 months (Nov ~ Mar, 3,600 hours)
- Data based on 18HP model heating
DVM PLUS IV adopts a new compressor that is optimized
with eco-friendly R410A refrigerant, which has a “0” ODP
value, to minimize environmental pollution. This also improves
refrigerant operation efficiency and performance.
Samsung minimizes the use of toxic substances such as
mercury, lead, and cadmium, attaining RoHS certification with
its excellent eco-friendly technology.
SAMSUNG invests significant efforts to help save the
environment and comply with the WEEE Directive by joining or
establishing recycling schemes for each country.
20,714
8.8%
18,900
SAMSUNG
Company A
0.05
R22
Ozone
Depletion
Potential
0
R410A
Ozone
Depletion
Potential
(ODP)
RoHS(Restriction of Hazardous
Substances Directive)
RoHS sets eco-friendly regulations that
ban the use of toxic substances, such
as mercury, lead, and cadmium, that are
obstacles in electronic recycling.
CO
2
Emission