FX-100
Fiber Sensor
Amplifi ers
The emitted light and output indicator flash 
at the same frequency.
Attenuation function [SET mode]
If the light receiving level becomes saturated when 
sensing over short distances or when sensing 
transparent objects or minute objects, the light emitting 
amount can be reduced so that stable sensing can be 
provided without needing to change the response time.
Teaching using ON / OFF buttons [SET mode]
Simply press the ON button when an object is present 
and OFF when it is not. There is no need to switch 
settings or make judgments between Light-ON (
) 
and Dark-ON (
).
Interference prevention function [SET mode]
The emission frequencies can be set separately for 
each unit in order to avoid interference. The emitted light 
fl ashes while setting is in progress, so that you can see 
at a glance which fi ber sensor is currently being set. 
In addition, this interference prevention is not done by 
using optical communication. This means that there is no 
need to place the amplifi ers close together like there was 
before, and so the amplifi ers can be set up apart from 
each other.
FX-101□: Interference prevention for up to 3 units 
FX-102□: Interference prevention for up to 4 units
Multi-function external input [PRO mode]
Settings such as emission 
halt, limit / auto teaching 
and ECO settings can be 
carried out via external 
input.
(Brown) +V
(Blue) 0 V
(White) External input
(Black) Output
External input lines are
equipped as standard
Alert function [PRO mode]
When the amount light received approaches the 
threshold value, the display can be made to blink in 
order to alert the operator.
* When the emission frequencies are changed, the response times will 
also change.
Thru-beam type / Retroreflective type
<Setting example>
Reflective type
Object present ON Object absent OFF
Object present ON Object absent OFF
Limit teaching function
This carries out teaching and sets threshold values only 
when no object is present (when the incident light amount 
is stable). This is useful when sensing objects if there 
are other objects in the background and when sensing 
minute objects. Teaching can also be carried out using 
external input.
Threshold tracking function [PRO mode]
This function seeks changes 
in the light emitting amount 
resulting from changes in 
the environment over long 
periods (such as dust levels), 
so that the incident light 
intensity can be checked 
at desired intervals and the 
threshold values can be reset 
automatically.
Time
Current value
The amount of light
received when there 
is no object
Incident light intensity
Threshold value
GETA function [PRO mode]
The display value for the incident light intensity can be offset 
by the desired value (target value). The target value can be set 
to between 0 and 2,000 (in increments of 100). For example, if 
the incident light intensity is 1,500 and the target value is set to 
2,000, then “2,000” will appear in the digital display.
Unify at 500 using 
the GETA function
Variations in the amount of light received
<When using at a shift amount of 20% and a threshold value of 1,000>
The amount of light received ranges from about 900 to 1,100 
when the digital indicator flashes.
Range of the digital indicator flashing
(margin: small)
1,100 approx.
900 approx.
Threshold value
of 1,000
The digital indicator flashes.
Incident light intensity