Specifications
135
Digital Fiber Sensor FX-100 SERIES
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
SAFETY
COMPONENTS
PRESSURE
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
WIRE-
SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
Selection
Guide
Fiber Sensor
Amplifiers
FX-300
FX-100
Fibers
FT / FD / FR
FX-410
FX-311
FX-11A
FX-301-F
Other
Products
FIBER
SENSORS
FX-100
Fiber sensor
Ampilifi ers
  PRECAUTIONS FOR PROPER USE 
Refer to p.986~ for general precautions, and to the “Operation Guide” or “SUNX website”
(http://www.sunx.com) for details pertaining to operating instructions for the amplifi er.
Never use this product as a sensing device 
for personnel protection.
In case of using sensing devices for 
personnel protection, use products which 
meet laws and standards, such as OSHA, 
ANSI or IEC etc., for personnel protection 
applicable in each region or country.
•
•
The FX-100 series does not use the horizontal 
connectors that are used with the FX-300 / FX-400 
series. Please note that horizontal connection cannot be 
performed using a connector attached cable. In addition, 
the optical communication function is not equipped on 
the FX-100 series, so it is unable to perform interference 
prevention for use with the FX-300 / FX-400 series. 
If using the FX-100 series together with the FX-300 / 
FX-400 series side-by-side, please set the same models 
together in groups.
•
Using in combination with the FX-300 / FX-400 series
Mounting
<When using a DIN rail>
How to mount the amplifi er
1
 Fit the rear part of the mounting 
section of the amplifi er on a 35 mm 
1.378 in width DIN rail.
2
 Press down the rear part of the 
mounting section of the unit on the 
35 mm 
1.378 in width DIN rail and 
fi t the front part of the mounting 
section to the DIN rail.
Part description
Setting mode
Setting mode appears after the MODE key is pressed for 
2 sec. in RUN mode.
•
Setting item
Factory setting
Description
Teaching 
mode
Threshold value can be set in 2-level teaching, 
limit teaching, or full-auto teaching.
Output 
operation 
setting
[Dark-ON]
Light-ON or Dark-ON can be set.
Timer 
operation 
setting
[Without timer]
Without timer, ON delay timer, or OFF delay 
timer can be set.
Timer 
setting
[ON-delay timer: 10 ms]
[OFF-delay timer: 10 ms]
In case of setting ON-delay timer or OFF-delay 
timer in the timer operation setting mode, timer 
can be set. When timer is not set, this mode is 
not displayed.
Emission
amount 
setting
[OFF]
Setting for reduced intensity of emission 
amount is possible when the incident light 
intensity is saturated.
Emission
frequency
setting
FX-101□
0 (Response time: 
250 μs or less)
FX-102□
1 (Response time: 
2.5 ms or less)
In case of using the fi ber heads in parallel, 
interference can be prevented by setting 
different emission frequency. However, when 
emission frequency 0 is set, interference 
cannot be prevented. Response time 
corresponds to emission frequency. For 
details, refer to “
SPECIFICATIONS” on p.132.
Operation indicator 
(Orange)
MODE key
ON key / 
Setting value UP key
OFF key / 
Setting value DOWN key
Digital display (Green) 
(Threshold value)
Digital display (Red) 
(Incident light intensity)
35 mm 1.378 in width DIN rail
1
2
How to remove the amplifi er
1
 Push the amplifi er forward.
2
 Lift up the front part of the 
amplifi er to remove it.
Note: Take care that if the front part is lifted without pushing the amplifi er 
forward, the hook on the rear portion of the mounting section is likely 
to break.
<When using screws with washers>
Use M3 screws with washers 
for mounting. The tightening 
torque should be 0.5 N·m or 
less.
•
1