Specifications

33
High Performance Liquid Chromatograph
20 MPa 35 MPa 20 MPa 35 MPa
Total-volume sample injection, variable injection volume
0.1 to 100 µL (standard), 0.1 to 2,000 µL (option)
1% max (specified conditions)
RSD: 0.3% max. (specified conditions, typically 0.2% RSD max)
0.005% max. (specified conditions, typically 0.0025% max)
30 max. per sample
Set freely before and after sample injection.
pH1 to pH14
4 to 35°C
Injection method
Maximum operating pressure
Injection-volume setting range
Number of processed samples
Injection-volume accuracy
Injection-volume precision
Sample Carryover
Number of repeated injections
Needle rinsing
Sample cooler
Operating pH range
Operating temperature range
Dimensions, weight
Power requirements
SIL-20A (228-45006-XX) SIL-20AHT (228-45119-XX)
175 (1 mL vials), 105 (1.5 mL vials), 50 (4 mL vials)
192 (two 96-well MTP/DWP), 768 (two 384-well MTP/DWP)
Also, ten 1.5 mL vials in addition to each of the above.
None
W260 × D500 × H415 mm, 27 kg
AC 110 V, 230 V, 100 VA, 50/60 Hz
175 (1 mL vials), 70 (1.5 mL vials), 50 (4 mL vials)
192 (two 96-well MTP/DWP), 768 (two 384-well MTP/DWP)
Also, ten 1.5 mL vials in addition to each of the above.
Block cooling/heating,
used together with defumidifying function, 4 to 40°C
W260 × D500 × H415 mm, 30 kg
AC 110 V, 230 V, 300 VA, 50/60 Hz
SIL-20AC (228-45007-XX)
SIL-20ACHT (228-45120-XX)
* Prominence UFLC system uses SIL-20AHT UFLC version (228-45132-xx) or SIL-20ACHT UFLC version (228-45133-xx), which has outlet piping optimized for
UFLC in standard SIL-20A or SIL-20AC.
N
u
Op
Autosamplers SIL-20A / 20AC / 20AHT / 20ACHT
P. 8
P. 8
Compatible plates
Number of processed plates
Sample cooler
Operating temperature range
Dimensions, weight
Power requirements
Rack Changer II (228-45164-XX)
96-well MTP, 96-well DWP, 384-well MTP, 384-well DWP, 1.5 mL vial plate (54 vials)
12
Block cooling/heating, used together with dehumidifying function, 4 to 40°C
4 to 35°C
W425 × D500 × H415 mm, 32 kg
AC 110 V, 230 V, 350 VA, 50/60 Hz
Rack Changer II
Connectable units
Number of connectable units
Data buffering
Event I/O
Analog boards
Operating temperature range
Dimensions, weight
Power requirements
Solvent delivery units: 4 max.;
Autosamplers: 1; Column ovens: 1;
Detectors: 2 max.; Fraction collectors: 1;
Sub-controllers: 2 max.
8 (expansion possible up to 12)
4 inputs, 4 outputs
Up to 2 boards can be mounted.
W260 × D420 × H140 mm, 5.5 kg
AC 110 V, 230 V, 100 VA, 50/60 Hz
CBM-20A (228-45012-XX) CBM-20Alite (228-45011-38)
Solvent delivery units: 4 max.;
Autosamplers (SIL-10AF/10AP/10Ai): 1;
Column ovens: 1; Detectors: 2 max.
5 (including the unit incorporating the system controller)
2 inputs, 2 outputs
Mounting not supported.
W120 × D100 × H20 mm, 0.5 kg
Supplied from unit
Approx. 24 hours for one analysis (at 500-ms sampling rate; available only with LCsolution)
4 to 35°C
System Controllers CBM-20A / 20Alite
P. 10
Nu
Op
CBM-20A