Instruction manual

13
M
J
A
2 - Adjusting of primary air
of the top burners
By operating the screw “M”, reset the air
adjuster “A” according to the instructions
see “TABLE FOR THE CHOICE OF THE
INJECTORS”, where the distance
between injector and air adjuster is rec-
ommended (in mm).
Before lowering the hob top, set the
burners on their sites and light them in
order to check whether the flames are
correct, as per the specifications given at
page 12.
In case of uncorrect flame, lift or lower
the air adjuster.
3 - Adjusting of the
minimum of the top burners
Considering that in the minimum position
the flame must have a length of about 4
mm and must remain lit even with a
brusque passage from the maximum
position to that of minimum.
The flame adjustment is done in the fol-
lowing way:
– Turn on the burner
– Tum the tap to the MINIMUM position
– Take off the knob
– With a small flat screwdriver turn the
screw inside the tap rod to the correct
regulation (fig. 3.6).
Normally for LPG, tighten up the regula-
tion screw.
Fig. 3.5 Fig. 3.6