Instruction manual
12
Flame faulty in Flame correct Flame with excess
primary air primary air
long, yellow and trembling clear interior blue cone short and sharp
too blue interior cone
tending to detach
CAUSE
air regulating tube, correct distance air regulating tube,
too closed of the tube too open
1 - Injectors replacement of top burners
This appliance is suitable for use with natural gas or LPG (check the “gas type” sticker
attached to the appliance).
The nominal gas consumption and injector size details are provided in table at page 15.
To replace the injectors it is necessary to lift the cooktop and proceed as follows:
■ Remove the backguard “G” (Fig. 3.3).
■ Remove pan supports and burners from the cooktop.
■ Unscrew the two screws “B” and remove the sockets (Fig. 3.3).
■ Unscrew the two screws “C” and remove the two side trims and joints pulling upwards.
■ Pull forwards the hobtop to release it, then lift following arrow “D” (Fig. 3.3).
■ Hold the hobtop open by a support (Fig. 3.4).
■ Fully raise the adjusting air tube A (fig. 3.5) in order to easily reach the injector.
■ Using a 7 mm A/F angled spanner, remove the injector from its housing and replace it
one according to the kind of gas (see following tables - page 15).
C
C
B
B
V
G
D
Fig. 3.3
Fig. 3.4