User Guide
Installation - Flow Controls
- 12 -
Max. 25ft
FCD Air Intake
PDI
External Flow
Control. Located
as close as possible to
the last fixture
Cleanout Cleanout
Sink
Flow
Max. 25ft
(for PDI)
PDI
External Flow
Control installation
Cleanout
Cleanout
FCD Air Intake
Sink
Inlet
Outlet
External Flow
Control:
When installed with an
External Flow Control, the
internal ow control plate and
seal shown above are removed
during installation.
With the internal ow control plate
removed, the ow control function
will now be performed by a separate
device that will be installed upstream
from the interceptor. This is located as
close as possible to the appliances and
xtures being served, but after the last
branch connection to the main drain
line connected to the interceptor. The
ow control shall be installed so as to
remain accessible for maintenance and
will typically be recessed into the oor.
The location of the cleanout should
be recorded in you Installer Hand over
Check List (See Page 14)
With an external ow control in particular, it
is important that it be opened and checked
periodically (min. twice annually) to ensure
there is no build up or blockage occurring that
will restrict the ow.
Remove
ow control
plate
Remove
ow control seal
Flow Controls
Depending on preference or requirement
Endura® XL can be operated with an internal
or external ow control. All models are
supplied with an internal ow control.
Internal Flow Control:
The internal ow control is located inside the dynamic inlet bae,
axed to the downstream part that moves forward when the
bae is opened.
The ow control is an essential part
of the hydromechanical grease
interceptor and its function.
Flow
control
plate
Flow
control
seal
Inlet