Product Overview
Canplas Industries Ltd.
P.O. Box 1800, 500 Veterans Drive
Barrie, Ontario, Canada L4M 4V3
Tel: (705) 726-3361
1-800-461-5300
Fax: (705) 726-2186
GD-02048-07-15 PRINTED IN CANADA
Canplas LLC
11402 East 53rd Ave., Suite 200,
Denver, CO, U.S.A. 80239
Tel: (303) 373-1918
1-888-461-5307
Fax: (303) 373-1923
Capacities
Approvals
Dimensions
An Environmentally
Responsible Choice
The Endura XL tank is an environmentally
conscious solution, molded with
recompounded PE material, where
availability allows.
Specications Made Easy
The Endura series grease interceptors are
listed on the ARCAT website that oers a
wide variety of tools for the specication
community with the most extensive and
up to date specication library.
CAD BIM SPECS
Average Eciency % (ASME A112.14.3) 98% 99%
Operating Temperature Capabilities
(Intermittent discharge)
160˚F
(71˚C)
160˚F
(71˚C)
Cover Load Capacity
(Third Party Tested)
> 20,000 lbs
(9072 kgs)
> 20,000 lbs
(9072 kgs)
Unit Weight (Empty) 233 lbs
(106 kgs)
283 lbs
(128 kgs)
Liquid Capacity 158 gal
(598 L)
257 gal
(973 L)
Connection size (mechanical) 4” 4”
XL75 XL100
Part Number
Add Sux “T” For FPT Connections
4075A04
4075A04T
40100A04
40100A04T
Flow Rate (GPM)
75 100
Flow Rate (L/Sec)
4.74 6.3
CAPACITY - Lbs (MIN)
150 200
CAPACITY - Kg (MIN) 68 91
CAPACITY - Lbs (Actual - ASME A112.14.3) 559lbs 1058lbs
CAPACITY - Kg (Actual - ASME A112.14.3) 253kg 480kg
Solids Capacity lbs (Kg) estimated 260lbs (118kg)
45 Gallons
350lbs (159kg)
60 Gallons
Specication:
Sample specication clause.
Contractor shall install a Canplas Endura® XL Hydromechanical Grease Interceptor (HGI), Part No. 40100A04
q
,
40100A04T
q
, 4075A04
q
, 4075A04T
q
(Indicate as applicable), and rated to 100GPM
q
75GPM
q
(Indicate as
Applicable) independently third-party certied to the current version of PDI-G101, ASME A112.14.3 and CSA B481.1.
Approved alternate is permissible providing written compliance to the following is provided and validated.
Where an internal ow control is desirable and acceptable to the Authority Having Jurisdiction (AHJ), the interceptor
shall be rated and approved to ASME A112.14.3 Type C. The ow control shall be accessible for cleaning and inspection
up to the maximum burial depth of 72” regardless of the application and when requiring Riser Extension, the installing
contractor will extend the opening device according to manufacturers published instructions. The outlet system will provide
facility for connections to be made perpendicular to the inlet connection. Connection formats will be compliant with
requirements of AHJ and the performance standards identied above. Contractor shall provide mechanical joint connectors
or requisite materials to connect the grease interceptor to the drainage system, additionally making adequate provision for
management of food debris and solids.
Interceptor shall be furnished with two (2) trac rated access covers, maximizing internal visibility for inspection and
maintenance when removed. These covers shall be capable of withstanding a proof load of 20,000lbs, being qualied for
application at temperatures from -20˚F to +100˚F (-29˚C to +38˚C). The cover will be mechanically secured when operational.
The interceptor tank shall be constructed with seemless engineering thermoplastics, evaluated and approved to the
material performance requirements of CSA B481.0
The interceptor shall additionally; operate with an air-balanced environment to equalize variation in internal pressures
being controlled and maintained with an appropriately sized air balance means; be supported by a Lifetime Warranty
against manufacturing defect.
For approved Plumbing & Drainage Institute (PDI) installation, an accessible ow control 40442100A
q
, 4044275A
q
40442100AT
q
, 4044275AT
q
(Indicate as applicable) with molded orice and removable access cap will be installed
upstream of the interceptor, being vented and installed according to manufactures instructions and the currently
published version of PDI G101 Interceptor will be located within 25ft developed pipe run of the last connected appliance
for operational compliance. Where applicable a secondary ow control will be employed in installations where there is
greater than 8ft of vertical elevation between the kitchen discharge appliances and the interceptor inlet.
®
26”
22”
34.5”
48.5”
84.5”
50”
72” Max
Burial Depth
72” Max
Burial Depth
78”
48.5”
50”
26”
22”
14”
14”
29”
79”
32”
39.5”
59”
43”
32”
We reserve the right to make part modications without prior notice. Drawings for illustrative purposes only. All Dimensions are for illustrative purposes only, temperature will cause some variations.