Overview of Primary Product
SIDE VIEW
E
B
B
A
F
G
D
C
FRONT VIEW
PRY
HERE
PRY
HERE
Model
3925XTA03
shown
25 XT Grease Interceptor
CSA B481.1
Grease Capacity Min - lb (kg): Industry
minimum grease capacity based on GPM
ow rate. Requires minimum 2 lb of grease
capacity for each GPM of ow.
Grease Capacity Actual - lb (kg): Actual capacity
at breakdown when tested to ASME A112.14.3
Eastern U.S. Customers
Tel: (289) 881-0120
Toll Free: 1-800-463-9572
Fax: (905) 844-0826
Western U.S. Customers
Tel: (303) 373-1918
Toll Free: 1-888-461-5307
Fax: (303) 373-1923
www.ipexna.com | sales@ipexamerica.com
GD-004000-10-16Endura®brandproductsmanufacturedbyCanplasIndustriesLtd.
FLOW CONTROL DIMENSIONS
AIR INTAKE
DIMENSIONS
NOM. Pipe Size 1 Piece
Compact
2” h x h
2 Piece
2” h x h
2 Piece
3” h x h
A 3.94”
(100mm)
3”
(76.2mm)
4.23”
(107.4mm)
B 3.44”
(87.4mm)
3.84”
(97.5mm)
5.93”
(151mm)
C - - -
B
A
B
C
A
FLOW CONTROL
AIR INTAKE TEE
3” VERSION ILLUSTRATED
• Flow Control
• Air Intake Tee
1 Piece Compact Flow
Control
(2” Version Illustrated)
2 Piece Flow Control
(3” Version Illustrated)
A
B
A 2”, two piece ow control
is also available for purchase.
Email:tech-support@endurainterceptor.com
See U39 Pricelist for details
CAPACITIES
DESCRIPTION Endura 25-02 Endura 25-03
• Part Number 3925XTA02 (2”) 3925XTA03 (3”)
US Gallons Per Minute - GPM (L/Sec) 25 (1.6) 25 (1.6)
Min. Grease Capacity - lb (kg) 50 (22.68) 50 (22.68)
Grease Capacity Actual - lb (kg) 72.55 (32.90) 73.01 (33.11)
Average Eciency % (ASME A112.14.3) 96.7% 97.3%
Operating Temperature Capabilities
220˚F
(104˚C)
220˚F
(104˚C)
Cover Load Rating- CSA B481.0
(Proof Load for Approval)
440 lb
(200 kg)
440 lb
(200 kg)
Unit Weight (Empty) - lb (kg) 35.61 (16.153) 37.77 (17.136)
Liquid Capacity - gal. (L) 30.6 (115.83) 29.5 (111.67)
Connection size (mechanical joint only) 2” 3”
Contractor shall install Endura 25XT Grease Interceptor, Part Number:
3925XTA02 3925XTA03 – (mark as applicable) supplied with
operationally accessible external ow control device and installed per
manufacturer’s instructions. The interceptor tank shall be of single piece
injection molded thermoplastic construction, capable of withstanding constant
discharge temperatures up to 212˚F (104˚C). The interceptor shall incorporate
a CSA B481.0 approved cover with cam-latch access system and be capable
of supporting 440lb (220kg). Endura modular riser extensions part number
3925AX6 - Enter Quantity: __________ , are are not required
for this installation – refer to manufacturers installation instructions. The
interceptor shall be tested and approved to the current version of PDI-G101,
ASME A112.14.3 and CSA B481 and manufacturer will provide option for
extended warranty for a period of 10 years from date of installation. Contractor
to provide locally approved mechanical joint couplings for connection of
adjacent piping system to the grease interceptor.
SAMPLE SPECIFICATION
CADBIMSPECS
.com
®
L L
2” spg x h 3” spg x h
2.91”
(73.9mm)
2.67”
(67.8mm)
2.71”
(68.8mm)
4.01”
(101.9mm)
2.24”
(56mm)
2.27”
(57.7mm)
TANK
DIMENSIONS
3925XTA02 (2”) 3925XTA03 (3”)
A 31.25” (793.75mm)
B 18.5” (469.9mm)
C 4” (101.6mm) 4.5” (114.3mm)
D 12.5” (317.5mm) 12” (304.8mm)
E 16.5” (419.1mm)
F 28” (711.2mm)
G 15.5” (393.7mm)