Product Overview
GD-01030-07-18
This unit is designed for use with inlet waste connections up to 1½” diameter the inlet connection being made with a
exible no-hub coupling (not supplied). Based on the outside diameter of the inlet/outlet these ttings will need to be
either 2” x 1 ½” or 2” x 1 ¼” reducing style couplings and are available from most plumbing wholesalers or DIY outlets.
DO NOT decrease the pipe diameter across the unit – i.e. inlet vs. outlet. Please Note : The Endura® Plaster Trap is
made of polypropylene which will not accept solvent weld cement.
Based on the use of 1½” pipe the maximum ow rate that can enter and pass through this unit is 20GPM.
Unlike a grease interceptor no ow control device is necessary in this application.
Servicing & Maintenance
Your Endura® Plaster Trap will require periodic servicing
to remove accumulated material and maximize its
ongoing eectiveness. This process can be achieved
manually by bailing out excess water, collecting
accumulated debris to a suitable container by hand
for disposal/re-use, or using a suitable wet vacuum
extraction unit. Alternatively a contractor can be usually
found locally who can use an industrial vacuum method
to remove and dispose of the entire contents on a
regular basis.
Ensure that you check the outlet screen during this
process and clean the lter mesh accordingly. It will be
necessary to check the operation of the Plaster Trap on a
weekly basis for the rst 6-8 weeks following
commissioning. This will allow you to assess the on
going schedule of maintenance.
Plaster Trap
Plaster Trap
3910PA15
A 14.5”
(368mm)
B 17.5”
(444mm)
C 3.5”
(89mm)
D 12.8”
(325mm)
E 16.3”
(414mm)
3920PA15
A 23.6”
(600mm)
B 17.5”
(151mm)
C 3.5”
(89mm)
D 12.8”
(325mm)
E 16.3”
(414mm)
Tank Dimensions
Endura® is a registered trademark.
Canplas Industries Ltd.
Separation Technologies Group
500 Veterans Drive, PO Box 1800
Barrie, ON L4M 4V3 Canada
Tel: (705) 726-3361
Toll Free: 1-800-461-5300
Fax: (705) 726-2186
Technical Support