Owner Manual
Installation Instructions
Start Here
Glass and Bulb Installation
1. With a Phillips screw driver, remove flat head screw on the
underside of the fixture.
2. Remove the front plate.
3. Insert the bulb into the socket.
4. Slide the glass in the glass track at the back of the fixture.
5. Once the glass is in place, re-assemble the front plate and
screw.
Luminaire Mounting
(For typical ground spike mounting)
Front
Plate
Screw
Glass
1. To prevent electrical shock, disconnect the transformer
from the electrical supply before installation or service.
2. Run wire from luminaire through mounting hole in the top
of the ground spike.
3. Attach luminaire to ground spike by threading to mounting
hole in spike and locking it in place.
4. Place spike in desired position and insert into ground until
the ange of spike is flush with g round.
5. Strip the two wire leads from the luminaire and connect to
the main supply wire using the provided silicone filled wire
nut.
Note: Wire is to be protected by routing in close proximity to
the luminaire or fitting or next to a building structure
such as a house or deck. Wiring should be buried a
maximum of 6 inches (15.2 cm) in order to connect to
main supply wire. The main supply wire must have its
length cut off within 6 inches (15.2 cm) from a building
structure, a luminaire or fitting.
Silicone filled
Wire nut
Fixture Wire
Supply Wire
Fixture Body
Bulb