Setup guide

-47-
MediaEdge
4 Maintenance Mode
4-1 Maintenance Mode overview
MediaEdge-STB3 Maintenance Mode is the recovery program that is used when
the fi rmware update, as described in the previous section “Updating Firmware,” has
failed and MediaEdge-STB3 no longer functions. It is also used when you forget the
user name and password that you have set in the [User name and Password]
screen.
Firmware updates, in this case, are performed in a special Maintenance Mode with
a fi rmware binary fi le rather than an archive fi le.
Connections and Settings
(1) Use a serial cross cable to connect the MediaEdge-STB3 to a computer
featuring a RS-232C port.
(2) Start a terminal communication program on the computer.
The communication parameters to use are as follows:
Baud rate: 115200bps
Data bit: 8 bit
Stop bits: 1
Parity: None
Flow control: None
Warning:
While in Maintenance Mode, do not perform operations other than the ones described in
this section. Doing so may damage the fi rmware.