Technical information
4-42
SmartBase MPC600F/MPC400 Chapter 4: Maintenance & Service
5.2.5 New SSSWs/parameters added to this model
#1 SSSW (service soft switch setting)
SW01 (service soft switch 01: error management)
Bit Function 1 0
0 Service error code Output Not output
1 Error dump list Output Not output
2 Not used
3 Copy function No Yes
4 (New) ##300 series service error code Output Not output
5 Not used
6 Not used
7 User setting restriction Setting possible Setting restricted
[Bit 4]
Even when Bit0 is set to "Not output", you can select whether or not to output ##300 series Service
Error Codes, caused by hardware malfunction.
When "Output" is selected, ##300 series Service Error Codes are displayed and in reports.
When "Not Output" is selected, no Service Error Codes are displayed.
#1 SSSW (service soft switch setting)
SW15 (service soft switch 15: Dial-in FAX/TEL switching function setting)
Bit Function 1 0
0 Not used
1 Not used
2 Not used
3 Not used
4 Not used
5 Not used
6 (New) Detect continuous signal at Yes No
FAX/TEL switching
7 Not used
[Bit 6]
You may enable or disable detection of ROT continuous signal for FAX/TEL switching.
Normally, only ROT intermittent signals are detected for FAX/TEL switching. If you need to
detect both in view of exchange specifications, select to enable detection.