#3 NUMERIC Param.
01:
02:
03:
04:
05:
06:
07:
08:
09:
10:
11:
12:
13:
14:
15:
16:
17:
18:
19:
20:
21:
22:
23:
24:
25:
26:
27:
28:
29:
30:
0
10 (10%)
15 (15 lines)
12 (12 times)
4 (4 seconds)
4 (4 seconds)
(1~ 60)
(1~ 60)
350
0
6 (6 digits)
5500 (55 seconds)
3500 (35 seconds)
0
1300
0
120 (1200 ms)
2 (2 seconds)
100 (1000 ms)
0 (0 ms)
400 (4000 ms)
100 (1000 ms)
0 (0ms)
400 (4000 ms)
44
10
60 (600 ms)
44
0
0
0
10
Not used
RTN signal transmission condition (1)
RTN signal transmission condition (2)
RTN signal transmission condition (3)
Pause time for NCC (after the ID code)
Pause time for NCC (after the ID code)
Not used
Not used
The number of digits in telephone number
compared against TSI signal to be matched
for restricted receiving function
Line connection detection time (T0 timer)
T1 Timer (Rx)
Not used
Not used
Not used
Hooking detection time
Pseudo RBT transmission from CML on time
until start
Pseudo RBT signal pattern: On time
Pseudo RBT signal pattern: Off time (short)
Pseudo RBT signal pattern: Off time (long)
Pseudo ring pattern: On time setting
Pseudo ring pattern: Off time (short)
Pseudo ring pattern: Off time (long)
FAX/TEL switching function signal detection level
Pseudo-RBT signal transmission level
Answering machine connection function
signal detection time
Not used
Not used
Not used
Not used
Not used
(Numeric parameter settings)
Default Range
(1~ 99)
(2~ 99)
(1~ 99)
(1~ 20)
(0~ 9999)
(0~9999)
(0~ 999)
(0~ 9)
(0~ 999)
(0~ 999)
(0~ 999)
(0~ 999)
(0~ 999)
(0~ 999)
(Do not change)
(0~ 20)
(0~ 999)
(Do not change)