Technical information

4-20
SmartBase MPC600F/MPC400 Chapter 4: Maintenance & Service
No. Tx or Rx Definition
##283 [ TX ] Excessive repeat protocol during Tx
##284 [ TX ] DCN reception after TCF transmission
##285 [ TX ] DCN reception after EOP transmission
##286 [ TX ] DCN reception after EOM transmission
##287 [ TX ] DCN reception after MPS transmission
##288 [ TX ] Receive signals other than PIN, PIP, MCF, RTP or RTN after EOP
transmission
##289 [ TX ] Receive signals other than PIN, PIP, MCF, RTP or RTN after EOM
transmission
##290 [ TX ] Receive signals other than PIN, PIP, MCF, RTP or RTN after MPS
transmission
• Printer error codes
No. Tx or Rx Definition
##332 [TX/RX ] Printer control DRAM check error
##333 [TX/RX ] Printer control ROM check error
##334 [TX/RX ] Printer control EEPROM check error
##335 [TX/RX ] Data transmission error between the system control section and printer
control section
##336 [TX/RX ] BJ head abnormal temperature error
##337 [RX ] BJ head temperature sensor error
##342 [TX/RX ] Cleaning absorption waste ink capacity full
##345 [TX/RX ] BJ cartridge head cleaning error
##346 [TX/RX ] Inside temperature error
##348 [TX/RX ] Ink detection sensor error
• V.8/V.34 protocol error codes
No. Tx or Rx Definition
##670 [ TX ] At V.8 late start, the called party declares the V.8 protocol in DIS
signal and this unit transmits a CI signal, but the protocol does not
progress and a T1 time-out occurs.
##671 [ RX ] At V.8 termination, the protocol did not advance to phase 2 and a T1
time-out occurs after the caller CM signal was detected.
##672 [ TX ] The protocol did not move from phase 2 to phase 3 and a T1 time-out
occurred during V.34 transmission.
##673 [ RX ] The protocol did not move from phase 2 to phase 3 and a T1 time-out
occurred during V.34 reception.
##674 [ TX ] The protocol did not move from phase 3 to phase 4 and a T1 time-out
occurred during V.34 transmission.
##675 [ RX ] The protocol did not move from phase 3 to phase 4 and a T1 time-out
occurred during V.34 reception.
UNQ