5 Stringing the Guide Wire
The guide wire is 0.148 mm in diameter.
When stringing it, be sure to follow the order indicated in the figure.
Figure 11-232
6 Adjusting the Height of the Charging Wire
The height of the charging wire may be adjusted by turning the screw located behind
the charging assembly. A full single turn of the screw raises or lowers the charging wire
by about 0.7 mm.
Figure 11-233
2
871 4 10 11 13
3
569 12
B
A
A
B
Corona Unit Height of Standard Position
Primary A=10.6 ± 0.3mm
B=9.5 ± 0.2 mm
Transter