LV-7575 Expand Serial Command Functional Specifications

LV-7575 Expand Serial Command Functional Specifications
62/71
9.12.19 CR_PFAIL12 Command
Command “CR_PFAIL12” [CR]
Details Get the item name and status of Power Failure No.12
Acceptable “000_%1_%2” [CR]
%1
%1 ------ Item name of Power Failure (16-byte fixed length)
%2 ------ Power status (2-byte fixed length)
Power is failed: “NG”, Power status is normal: “OK”
Response
Unacceptable “Error Code” [CR]
9.12.20 CR_PFAIL13 Command
Command “CR_PFAIL13” [CR]
Details Get the item name and status of Power Failure No.13
Acceptable “000_%1_%2” [CR]
%1
%1 ------ Item name of Power Failure (16-byte fixed length)
%2 ------ Power status (2-byte fixed length)
Power is failed: “NG”, Power status is normal: “OK”
Response
Unacceptable “Error Code” [CR]
9.12.21 CR_PFAIL14 Command
Command “CR_PFAIL14” [CR]
Details Get the item name and status of Power Failure No.14
Acceptable “000_%1_%2” [CR]
%1
%1 ------ Item name of Power Failure (16-byte fixed length)
%2 ------ Power status (2-byte fixed length)
Power is failed: “NG”, Power status is normal: “OK”
Response
Unacceptable “Error Code” [CR]
9.12.22 CR_PFAIL15Command
Command “CR_PFAIL15” [CR]
Details Get the item name and status of Power Failure No.15
Acceptable “000_%1_%2” [CR]
%1
%1 ------ Item name of Power Failure (16-byte fixed length)
%2 ------ Power status (2-byte fixed length)
Power is failed: “NG”, Power status is normal: “OK”
Response
Unacceptable “Error Code” [CR]
9.12.23 CR_PFAIL16 Command
Command “CR_PFAIL16” [CR]
Details Get the item name and status of Power Failure No.16
Acceptable “000_%1_%2” [CR]
%1
%1 ------ Item name of Power Failure (16-byte fixed length)
%2 ------ Power status (2-byte fixed length)
Power is failed: “NG”, Power status is normal: “OK”
Response
Unacceptable “Error Code” [CR]