LV-7575 Expand Serial Command Functional Specifications
LV-7575 Expand Serial Command Functional Specifications
60/71
9.12.10 CR_PFAIL03 Command
Command “CR_PFAIL03” [CR]
Details Get the item name and status of Power Failure No.3
Acceptable “000_%1_%2” [CR]
%1
%1 ------ Item name of Power Failure (16-byte fixed length)
%2 ------ Power status (2-byte fixed length)
Power is failed: “NG”
Power status is normal: “OK”
Response
Unacceptable “Error Code” [CR]
9.12.11 CR_PFAIL04 Command
Command “CR_PFAIL04” [CR]
Details Get the item name and status of Power Failure No.4
Acceptable “000_%1_%2” [CR]
%1
%1 ------ Item name of Power Failure (16-byte fixed length)
%2 ------ Power status (2-byte fixed length)
Power is failed: “NG”
Power status is normal: “OK”
Response
Unacceptable “Error Code” [CR]
9.12.12 CR_PFAIL05 Command
Command “CR_PFAIL05” [CR]
Details Get the item name and status of Power Failure No.5
Acceptable “000_%1_%2” [CR]
%1
%1 ------ Item name of Power Failure (16-byte fixed length)
%2 ------ Power status (2-byte fixed length)
Power is failed: “NG”
Power status is normal: “OK”
Response
Unacceptable “Error Code” [CR]
9.12.13 CR_PFAIL06 Command
Command “CR_PFAIL06” [CR]
Details Get the item name and status of Power Failure No.6
Acceptable “000_%1_%2” [CR]
%1
%1 ------ Item name of Power Failure (16-byte fixed length)
%2 ------ Power status (2-byte fixed length)
Power is failed: “NG”
Power status is normal: “OK”
Response
Unacceptable “Error Code” [CR]