LV-7575 Expand Serial Command Functional Specifications
LV-7575 Expand Serial Command Functional Specifications
57/71
9.11.15 CR_SECURITY Command
Command “CR_ SECURITY” [CR]
Details Get ON/OFF setting status of Security on menu.
Acceptable “000_%1” [CR]
%1
“ON” ------------ PJ/USB are locked
“OFF” ----------- PJ/USB are not locked.
Response
Unacceptable “Error Code” [CR]
9.11.16 CR_PJLOCKNOW Command
Command “CR_PJLOCKNOW” [CR]
Details Get actual setting status of PIN code lock
Acceptable “000_%1” [CR]
%1
“LOCK” ------ PJ is locked
PIN code lock is set to ON1/ON2 on the menu and PJ PIN
code is not entered, therefore PJ is actually locked.
“FREE” ------- PJ is unlocked (either A or B)
A) PJ lock is set to OFF on the menu
B) PJ lock is set to ON1/ON2 on the menu, but PIN code
Lock mode is canceled because PJ PIN code is entered.
Response
Unacceptable “Error Code” [CR]
9.11.17 CR_PJLOCKMENU Command
Command “CR_PJLOCKMENU” [CR]
Details Get ON/OFF setting status of PIN code lock on menu
Acceptable “000_%1” [CR]
%1
“ON1” -------------------- PIN code lock ON 1 is set on the menu
“ON2” -------------------- PIN code lock ON 2 is set on the menu
“OFF” -------------------- PIN code lock OFF is set on the menu
Response
Unacceptable “Error Code” [CR]
9.12 Other Status Read Commands
9.12.1 CR_STATUS Command
COMMAND “CR_STATUS” [CR]
Detail
Get operating status of Projector
Same as “CR0” in basic command except error code follows it.
Acceptable “000_%1” [CR] Response
%1
“00” = Power ON
“80” = Standby
“40” = Countdown in process
“20” = Cooling Down in process
“10” = Power Failure
“28” = Cooling Down in process due to abnormal temperature
“88” =Standby after Cooling Down due to abnormal
temperature
“02” = Invalid RS-232C Command
“24” = Power Save/Cooling Down in process
“04” = Power Save
“21” = Cooling Down in process after turened Off due to lamp
failure
“81”= Standby after Cooling Down due to lamp failure