LV-7575 Expand Serial Command Functional Specifications

LV-7575 Expand Serial Command Functional Specifications
56/71
9.11.10 CR_ON-STA Command
Command “CR_ON-STA” [CR]
Details Get setting status of Power ON Start
Acceptable “000_%1” [CR]
%1
“ON” -------------------------- Power ON Start is ON
“OFF” ------------------------ Power ON Start is OFF
Response
Unacceptable “?” [CR]
9.11.11 CR_P-MANE Command
Command “CR_P-MANE” [CR]
Details Get setting status of Power management
Acceptable “000_%1” [CR]
%1
“OFF” ------------------------ Power Management is disabled
“READY” -------------------- Power Management is set to Ready
“SHUTDOWN” ------------ Power Management is set to Shut
Down mode
Response
Unacceptable “?” [CR]
9.11.12 CR_P-MANETIME Command
Command “CR_P-MAETIME” [CR]
Details Get setting time for starting Power Management function
Acceptable “000_%1” [CR]
%1 “001 – 030” ----------------------- 1 to 30 minutes
Response
Unacceptable “?” [CR]
9.11.13 CR_FANSPEED Command
Command “CR_FANSPEED” [CR]
Details Get selected Fan Contorol Speed mode.
Acceptable “000_%1” [CR]
%1
“MAX” ------------------------ Max mode is seleted
“NOR” ------------------------ Normal mode is selected
Response
Unacceptable “?” [CR]
9.11.14 CR_KEYDIS Command
Command “CR_KEYDIS” [CR]
Details Get status of RC/KEY (valid or invalid)
Acceptable “000_%1” [CR]
%1
“NONE” -------------------------- RC and KEY, both are valid
“RC” ------------------------------- RC is invalid
“KEY” ----------------------------- KEY is invalid
Response
Unacceptable “?” [CR]