LV-7575 Expand Serial Command Functional Specifications

LV-7575 Expand Serial Command Functional Specifications
43/71
9.5.4 CR_H-POS Command
Command “CR_H-POS” [CR]
Details Get value of Horizontal Position
Acceptable “000_%1” [CR]
%1
“0000 – nnnn”
(nnnn = Total Dots – Display area H)
Response
Unacceptable
“Error Code” [CR] ------ When command is not available in the
given condition (such as being selected input
“?” [CR] ------------------- When unknown command is received
9.5.5 CR_V-POS Command
Command “CR_V-POS” [CR]
Details Get value of Vertical Position
Acceptable “000_%1” [CR]
%1
“0000 – nnnn”
(nnnn = Total Line – Display area V)
Response
Unacceptable
“Error Code” [CR] ------ When command is not available in the
given condition (such as being selected input
“?” [CR] --------------------- When unknown command is received
9.5.6 CR_DDOTS Command
Command “CR_DDOTS” [CR]
Details Get value of Display Dots
Acceptable “000_%1” [CR]
%1
“0100 – nnnn”
(nnnn = Total Dots – Position H)
Response
Unacceptable
“Error Code” [CR] ---- When command is not available in the
given condition (such as being selected input
“?” [CR] -------------------- When unknown command is received
9.5.7 CR_DLINE Command
Command “CR_DLINE” [CR]
Details Get value of Display Line
Acceptable “000_%1” [CR]
%1
“0100 – nnnn”
(nnnn = Total Line – Position V)
Response
Unacceptable
“Error Code” [CR] ---- When command is not available in the
given condition (such as being selected input)
“?” [CR] -------------------- When unknown command is received