LV-7575 Expand Serial Command Functional Specifications
LV-7575 Expand Serial Command Functional Specifications
36/71
8.10.10 CF_P-MANETIME Command
Command “CF_P-MANETIME_%1” [CR]
%1
“01” - ”30” ----------------------- Directly specify setting time by the minute
“UP” ------------------------------- Increment value by 1
(Switched in 01→02→ --- → 30 → 01 order)
“DN” ------------------------------ Decrement value by 1
(Switched in 30→29→ --- → 01 → 30 order)
Details
Set time of Power Management time (Available only in the normal Power ON
status)
The status set by this command is stored in EEPROM and setting remains
effective even after the power is turned to ALL OFF status.
Acceptable “000” [CR]
Response
Unacceptable “Error Code” [CR]
8.10.11 CF_FANSPEED Command
Command “CF_FANSPEED_%1” [CR]
%1
“MAX” ------------------------------ Select maximum fan speed
“NOR” ------------------------------ Select normal fan speed
Details
Switch Fan Control Speed mode.(Available only in the normal Power ON status)
The status set by this command is stored in EEPROM and setting remains
effective even after the power is turned to ALL OFF status.
Acceptable “000” [CR]
Response
Unacceptable “Error Code” [CR]
8.10.12 CF_KEYDIS Command
Command “CF_KEYDIS_%1” [CR]
%1
“NONE” ----------------------- RC and KEY are both enabled.
“RC” ---------------------------- RC is disabled.
“KEY” -------------------------- KEY is disabled.
Details
Disable RC and/or KEY functions
(Available only in the normal Power ON status)
Acceptable “000” [CR]
Response
Unacceptable “Error Code” [CR]
8.10.13 CF_FDEFAULT Command
Command “CF_FDEFAULT_%1” [CR]
%1 “RST”
Details
Reset to Factory Default setting
(Available only in the normal Power ON status)
Acceptable “000” [CR]
Response
Unacceptable “Error Code” [CR]