LV-7575 Expand Serial Command Functional Specifications

LV-7575 Expand Serial Command Functional Specifications
33/71
8.10 Setting Command
8.10.1 CF_BACKGND Command
Command “CF_BACKGND_%1” [CR]
%1
“BLUE” -------------------- Select Blue Back
“USER” ------------------- Select User
“BLACK” ------------------ Select Black Back
“UP” ---------- Switch forward (Blue BackUserBlack BackBlue Back)
“DN” --------- Switch backward (Blue BackBlack BackUserBlue Back)
Details
Set Screen status for no signal.(Available only in the normal Power ON status)
The status set by this command is stored in EEPROM and the setting remains
even after the power is turned to ALL OFF status.
Acceptable “000” [CR]
Response
Unacceptable “Error Code” [CR]
8.10.2 CF_DISP Command
Command “CF_DISP_%1” [CR]
%1
“ON” ----------------------------- Select Display
“CNTDWNOFF” --------------- Select Count down Off
“OFF” --------------------------- Cancel Display
“UP” --------------- Switch forward (On Count down Off Off On ---)
“DN” --------------- Switch backward (On Off Count down Off On ---)
Details
Set Display mode.(Available only in the normal Power ON status)
The value set by this command is stored in EEPROM and setting remains effective
even after the power is turned to ALL OFF status.
Acceptable “000” [CR]
Response
Unacceptable “Error Code” [CR]
8.10.3 CF_LOGO Command
Command “CF_LOGO_%1_%2” [CR]
%1 “0000 – 9999” ------------- Directly set Logo PIN code
%2
“OFF” ---------------------------Cancel Logo display
“DFLT” ------------------------- Select Logo of Factory Default
“USER” ------------------------ Select User
“UP” ---------------------------- Select functions to choose forward
(OFF DFLT USER OFF --)
“DN” ---------------------------- Select functions to choose backward
(OFF USER DFLT OFF --)
Details
Set Logo mode.(Available only in the normal Power ON status)
The status set by this command is stored in EEPROM and setting remains
effective even after the power is turned to ALL OFF status.
Set Logo PIN code in %1.
When Logo Lock is enabled:
PIN code is matched ------------------------- Command is valid (Acceptable)
PIN code is mismatched-------------------- Command is invalid (Error code “102”)
PIN code is beyond %1 available range ------------ Command is invalid (Error
code”?”)
When Logo Lock is disabled:
PIN code is within %1 available range ------- Command is valid (Acceptable)
PIN code is out of %1 available range ------- Command is invalid (Error code “?”)
Note: When Logo Lock is enabled, matching Logo PIN code switches Logo but
Logo Lock is not cancelled (Lock status is kept).
Acceptable “000” [CR]
Response
Unacceptable “Error Code” [CR]