8.4.8 CF_COLTEMP Command
Command “CF_COLTEMP_%1” [CR]
%1
“000” ------------------------------ Xlow
“001”------------------------------- Low
“002”------------------------------- Mid
“003”------------------------------- High
Details
Set Color Temperature (Available only in the normal Power ON status)
The value set by this command will not be stored in the projector’s memory.
Therefore, when the power is turned to ALL OFF status, the value returns to the
original setting. (It is stored in Standby mode.)
Acceptable “000” [CR]
Response
Unacceptable “Error Code” [CR]
8.4.9 CF_NZRED Command
Command “CF_NZRED_%1” [CR]
%1
“OFF” ---------------- Cancel Noise Reduction
“L1” ------------------- Set Noise Reduction to L1
“L2” ------------------- Set Noise Reduction to L2
“UP” ------------------ Switch setting forward direction (OFF→L1→L2→OFF)
“DN” ------------------ Switch setting backward direction (OFF→L2→L1→OFF)
Details
Set Noise Reduction level (Available only in the normal Power ON status)
The value set by this command will not be stored in the projector’s memory
Therefore, when the power is turned to ALL OFF status, the value returns to the
original setting. (It returns to the original setting in Standby mode as well.)
Acceptable “000” [CR]
Response
Unacceptable “Error Code” [CR]
8.4.10 CF_PROGV Command
Command “CF_PROGV_%1” [CR]
%1
“ON” ----------------- Set Progressive scan to On.
“FILM” --------------- Set Progressive scan to Film.
“OFF” ---------------- Set Progressive scan to OFF.
“UP” ------------------ Switch setting forward direction (OFF→ON→FILM→OFF)
“DN” ------------------ Switch setting backward direction (OFF→FILM→ON→OFF)
Details
Set Progressive scan mode. (Available only in the normal Power ON status)
The value set by this command will not be stored in the projector’s memory.
Therefore, when the power is turned to ALL OFF status, the value returns to the
original setting. (It is stored in Standby mode.)
Acceptable “000” [CR]
Response
Unacceptable “Error Code” [CR]