LV-7575 BASIC SERIAL COMMAND FUNCTIONAL SPECIFICATIONS
LV-7575 Basic Serial Command Functional Specifications
11/26
6.4 Operation Requirements
In the following status of projector, Available Functional Execution Commands are limited.
Projector Status Available Functional Execution Commands
Standby Mode C00: POWER ON
Countdown in process
C00: POWER ON → Countdown is terminated
C01: POWER OFF
C02: POWER OFF → Countdown is terminated
C46: ZOOM -
C47: ZOOM +
C4A: FOCUS -
C4B: FOCUS +
C5D: LENS SHIFT +
C5E: LENS SHIFT -
Cooling Down in process NONE (No Execution)
Cooling Down due to Abnormal
Temperature
NONE (No Execution)
Abnormal Temperature Status NONE (No Execution)
Power-Save Cooling Down in process NONE (No Execution)
Power Save Status
C00: POWER ON
C01: POWER OFF
Cooling Down in process after OFF
operation due to Lamp Failure
NONE (No Execution)
Note) in above status, the projector returns [ACK] [CR] even if it receives the other command.
6.5 POWER ON Command
Command “C00” [CR]
Detail
Power ON
When already Power is ON, no operation is started.
When sending this command during Countdown in process, Countdown is
terminated.
Acceptable [ACK] [CR]
Response
Unacceptable “?” [CR]
6.6 POWER OFF Command (Quick POWER OFF)
Command “C01” [CR]
Detail
Power OFF (Standby)
This command executes Quick Power OFF operation without displaying “Power
OFF?” message, which is displayed when Power is turned OFF with ON-OFF
button of the projector or remote control.
Acceptable [ACK] [CR]
Response
Unacceptable “?” [CR]
6.7 POWER OFF Command
Command “C02” [CR]
Detail
Power OFF (Standby)
This command works the same way as when Power is OFF with ON-OFF button
of the projector and remote control.
(When the command is sent once, “Power OFF?” message is displayed. If this
command is sent again while “Power OFF?” message is displayed,
Power OFF
operation is executed.)
When sending this command during Countdown in process, Countdown is
terminated.
Acceptable [ACK] [CR]
Response
Unacceptable “?” [CR]