LV7565_Basic_Command_Specification
Basic Serial Command Specification Page 7 of 20
be available. C3C/C3D commands can
control ZOOM/FOCUS/LENS SHIFT.
Processing Cooling Down
None (Does not execute even if receiving a
command)
Processing Cooling Down due to
abnormal temperature
None (Does not execute even if receiving a
command)
Abnormal Temperature Status
None (Does not execute even if receiving a
command)
Processing Power Save - Cooling Down
None (Does not execute even if receiving a
command)
Processing Power Save
C00: POWER ON
C01: POWER OFF
Other Command: POWER ON
Processing cooling down after
turning off automatically due to
a lamp failure
None (Does not execute even if receiving a
command)
Notice)When the status is above, even if the projector receives other command in the above
status, the projector returns [ACK][CR]
6.5. POWER ON Command
Command “C00” [CR]
Detail
Power ON
When already Power ON, no need to do.
When sending this command during processing Count Down, Count Down is
terminated.
Acceptable [ACK] [CR]
Response
Unacceptable “?” [CR]
6.6. POWER OFF Command (Quick Power OFF)
Command “C01” [CR]
Detail
Power OFF (Standby)
When Power OFF with POWER button of the projector or the remote
control, ”Power OFF” will be displayed. However, as soon as this command
is sent, Quick Power OFF is executed.
Acceptable [ACK] [CR]
Response
Unacceptable “?” [CR]
6.7. POWER OFF Command
Command “C02” [CR]
Detail
Power OFF (Standby)
When Power OFF with POWER button of the projector or the remote
control, ”Power OFF” will be displayed. However, as soon as this command
is sent, Power OFF is executed.
Acceptable [ACK] [CR]
Response
Unacceptable “?” [CR]
6.8. INPUT 1 Command
Command “C05” [CR]
Detail Select Input 1
Acceptable [ACK] [CR]
Response
Unacceptable “?” [CR]