LV-7565Command

Expand Serial Command Specification Page 41 of 46
9.8.6. CR_VPOS Command
Command “CR_VPOS” [CR]
Details Read V-Position setting status
Acceptable “000_%1” [CR]
%1 “-64” ~ “064”
Response
Unacceptable “?” [CR]
9.8.7. CR_HSCALE Command
Command “CR_HSCALE” [CR]
Details Read H-Scale setting status
Acceptable “000_%1” [CR]
%1 “-32” ~ “032”
Response
Unacceptable “?” [CR]
9.8.8. CR_HPOS Command
Command “CR_HPOS” [CR]
Details Read H-Position setting status
Acceptable “000_%1” [CR]
%1 “-64” ~ “064”
Response
Unacceptable “?” [CR]
9.9. Lamp Series Status Read Command
9.9.1. CR_LAMPREPL Command
Command “CR_LAMPREPL” [CR]
Details Read Lamp replacement time information
Acceptable “000_%1” [CR]
%1
“1Y” ------- Over the lamp replacement time
“1N” ------ Haven not reached the lamp replacement time
Response
Unacceptable “?” [CR]
9.9.2. CR_LAMPMODE Command
Command “CR_LAMPMODE” [CR]
Details Read Lamp mode setting status
Acceptable “000_%1” [CR]
%1
“NORMAL” -------- Normal Lamp mode
“ECO” --------------- Silent Lamp mode
“AUTO” ------------- Auto Lamp mode
Response
Unacceptable “?” [CR]