Expanded_Serial_Command_Codes

Expand Serial Command Functional Specification Page 38 of 41
9.11.5. CR_LANG Command
Command “CR_LANG” [CR]
Details Get selected Language
Acceptable “000_%a” [CR]
%a
“ENG” --------- English is selected
“DEU” --------- German is selected
“FRA” --------- French is selected
“ITA” ---------- Italian is selected
“ESP” --------- Spanish is selected
“POR” --------- Portuguese is selected
“NED” --------- Dutch is selected
“SVE” --------- Swedish is selected
“JPN” --------- Japanese is selected
“CHI” --------- Chinese is selected
“KOR” --------- Korean is selected
“RUS” --------- Russian is selected
Response
Unacceptable “?” [CR]
9.11.6. CR_ON-STA Command
Command “CR_ON-STA” [CR]
Details Get ON Start setting
Acceptable “000_%a” [CR]
%a
“ON” --------- Set ON Start
“OFF” ------- Cancel ON Start
Response
Unacceptable “?” [CR]
9.11.7. CR_P-MANE Command
Command “CR_P-MANE” [CR]
Details Get Power Management setting
Acceptable “000_%a” [CR]
%a
“OFF” ---------------- Cancel Power Management
“READY” ------------ Power Management is Ready mode
“SHUTDOWN” ---- Power management is Shut Down mode
Response
Unacceptable “?” [CR]
9.11.8. CR_P-MANETIME Command
Command “CR_P-MANETIME” [CR]
Details Get the time to start Power Management
Acceptable “000_%a” [CR]
%a “001” – “030” ----- 1mininute to 30minutes
Response
Unacceptable “?” [CR]
9.11.9. CR_FANSPEED Command
Command “CR_FANSPEED” [CR]
Details Get Fan Control speed
Acceptable “000_%a” [CR]
%a
“MAX” ------- Fan Control speed Max.
“NOR” ------- Fan Control speed Normal
Response
Unacceptable “?” [CR]