Expanded_Serial_Command_Codes
Expand Serial Command Functional Specification Page 31 of 41
9.5. PC Status Read Command
9.5.1. CR_FSYNC Command
Command “CR_FSYNC” [CR]
Details Get Fine Sync value
Acceptable “000_%a” [CR]
%a “0000” – “0031”
Response
Unacceptable
“Error code” [CR] ---- Invalid
“?” [CR] ---------- When the Projector received unclear command
9.5.2. CR_TDOTS Command
Command “CR_TDOTS” [CR]
Details Get Total Dots value
Acceptable “000_%a” [CR]
%a
“nnnn” – “9999”
(nnnn = Display Dots + Horizontal Position)
Response
Unacceptable
“Error code” [CR] ---- Invalid
“?” [CR] ---------- When the Projector received unclear command
9.5.3. CR_CLAMP Command
Command “CR_CLAMP” [CR]
Details Get Clamp value
Acceptable “000_%a” [CR]
%a “0000” – “0127”
Response
Unacceptable
“Error code” [CR] ---- Invalid
“?” [CR] ---------- When the Projector received unclear command
9.5.4. CR_H-POS Command
Command “CR_H-POS” [CR]
Details Get Horizontal Position value
Acceptable “000_%a” [CR]
%a
“0000” – “nnnn”
(nnnn = Total Dots – Display Dots)
Response
Unacceptable
“Error code” [CR] ---- Invalid
“?” [CR] ---------- When the Projector received unclear command
9.5.5. CR_V-POS Command
Command “CR_V-POS” [CR]
Details Get Vertical Position value
Acceptable “000_%a” [CR]
%a
“0000” – “nnnn”
(nnnn = Total Line – Display Line)
Response
Unacceptable
“Error code” [CR] ---- Invalid
“?” [CR] ---------- When the Projector received unclear command