Expanded_Serial_Command_Codes
Expand Serial Command Functional Specification Page 29 of 41
9.4.4. CR_TINT Command
Command “CR_TINT” [CR]
Details Get Tint value of user control
Acceptable “000_%a” [CR]
%a “000” – “063”
Response
Unacceptable
“Error code” [CR] --- Invalid
“?” [CR] ---------------- When receives unclear command
9.4.5. CR_SHARP Command
Command “CR_SHARP” [CR]
Details Get Sharpness value of user control
Acceptable “000_%a” [CR]
%a “000” – “015”
Response
Unacceptable “?” [CR]
9.4.6. CR_GAMMA Command
Command “CR_GAMMA” [CR]
Details Get Gamma value of user control
Acceptable “000_%a” [CR]
%a “000” – “015”
Response
Unacceptable “?” [CR]
9.4.7. CR_WBAL-R Command
Command “CR_WBAL-R” [CR]
Details Get White Balance Red value of user control
Acceptable “000_%a” [CR]
%a “000” – “063”
Response
Unacceptable “?” [CR]
9.4.8. CR_WBAL-G Command
Command “CR_WBAL-G” [CR]
Details Get White Balance Green value of user control
Acceptable “000_%a” [CR]
%a “000” – “063”
Response
Unacceptable “?” [CR]
9.4.9. CR_WBAL-B Command
Command “CR_WBAL-B” [CR]
Details Get White Balance Blue value of user control
Acceptable “000_%a” [CR]
%a “000” – “063”
Response
Unacceptable “?” [CR]